Arrived today for service on 2 systems. Upstairs is a 2013 2.5 ton American standard down stairs is a 2013 3.5 ton American standard. Cleaned outdoor coil. Checked Freon amps on motors. Cleaned drain lines and pump. Replaced 40+5 capacitor and contactor on outdoor unit for upstairs and 5 mfd capacitor for blower motor on upstairs. Systems are working properly at this time. Membership Replace 2= contactors 40+5 capacitor on outdoor unit for upstairs system and 5 mfd capacitor on blower motor for upstairs system.
Pumping 750 gallon septic tank
Arrived today for no cooling. Replaced 60+5 capacitor on outdoor unit. Explained to customer to leave system turned off until the morning to let compressor cool off then turn system back on. I can’t cool off compressor because there’s no faucet on the building to hook up for water hose to reset Thermo overload switch inside the compressor.
Estimate to unstop Both shower upstairs. Unstop both showers with sewer machine everything is draining great now
Break room sink was clogged Unlocked and reset garbage disposal Ran cable down branch line
Checked out pressure on house and checked to master sinks to make sure they are working properly
Cut out section of pipe with prv and check valve Install new prv and check valve with new connections Materials - 2487.61$ Labor 2 lead techs 4 hours - 1,320$ Trip charge x 2 - 319.09$ Total - 4,126.70
Pressure regulator valve is faulty and needs to be replaced as well as the check valve
unstop urinal treat drain of urinal clean flush vavle i’m performance and safety testing
Arrived today for tuneup on 2 air conditioning systems. Cleaned outdoor units. Cleaned drain lines. Checked Freon amps on motors capacitors. Found capacitor is weak on upstairs blower motor and capacitor is weak on outside unit for upstairs. Gave customer options. System are working at this time. Membership on 2 systems yearly customer stated that he will replace capacitors himself.
Install 2 curtains fans 2 whips and connect all wires And existing sensors, Also we take down the old ones and install the new ones
On this job, we need to install two currents fans on the doors. We need to take the 201s down and hang it now the two new ones we need to round the whip from the junction box to this fans so we work on estimates and we will send it shortly
Arrived today for poor heating. Found Filters stopped and belts need replaced. Replaced 8=20X20X2 filters 8=16X20X2 filters and 2 belts A50 and A44. Checked systems everything is working properly at this time. 2022 units 4 Lennox gas package on roof.
repaired 2 inch main water line Brought machine out to cover pipe back up