5494 E. Lamona Ave., Ste. 126
Fresno, CA 93727
(559) 298-6305

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 64 customer reviews

Great service.

He was so polite and explained what he was going to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great serviceThis is the second time David has come to my house and he’s efficient and polite

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Good communication and service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was the best

Thanks to Service Tech David for a job well done.


Response from Rare Service Heating & Air Conditioning, INC:

Randy, We are so happy that you were satisfied with our technician David. We are happy to be your Service Provider! Rare Service Heating and Air Conditioning

  • Overall Experience
  • Quality
  • Price
  • Convenience

New A/C unit

When my A/C caught fire recently and died, I was quite concerned with the aspect of a small fire as well as purchasing a new A/C. My old unit was purchased from Rare A/C 20 yrs. ago. At that time their service was great! Nothing has changed! There service is still great as well as their personal interest in our situation. My new unit was in and working 36 hrs. later, with all of the paper work handled properly and efficiently. Great work Alex and employees at Rare Service. Thank you.


Response from Rare Service Heating & Air Conditioning, INC:

Leslie and Gloria, We are so pleased to hear that you were happy with our service! Thank you for choosing us as your Service Provider. Rare Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fall Maintenance

Technician was very nice.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Came and fixed it quickly.


Response from Rare Service Heating & Air Conditioning, INC:

Thank you for your response Sherril. We are happy to be your service provider. Rare Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

All pros, no cons. Tim is great.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The gentleman that came out was great

Came out did the work fast and was very professional. Had a great experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service

Great service and I trust the work done. Very reliable company.


Response from Rare Service Heating & Air Conditioning, INC:

Diane, We are very happy to hear that you were pleased with our work. Thank you for allowing us to be your service provider. Rare Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Performed Fall PM Cleaned electrical compartment Checked all wiring, good Checked temperature rise Supply air 107 Return 72 Rise of 35,good Need to come back to replace faulty limit switch Resident was quoted $377.00 Maintenance Complete at this time


Alexandra  C.

Alexandra C. Job Checkin

Blew through tub to clear Unit running as per manufacturer's specifications Checked temperature rise rated 25-55 Supply air 102 Return air 66 Rise of 36, good Job Complete


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident, no one home Left filter on porch Went to roof Cleaned electric compartment Checked compressor amps 10.1 rated 14.8 Condenser amps 1.0 rated 1.6 Checked dual capacitor 45+5 Herm 44.9,good Fan 5.1, good Temperature rise Supply 100° Return 75° Rise of 25,good Unit running as per manufacturer's specifications


Alexandra  C.

Alexandra C. Job Checkin

Upon arrival I checked in with Customers. I set up my ladder and equipment. Climbed up to the unit and started the PM . I removed and cleaned burners (5). I cleaned off flame sensor electrode. I cleaned off spark igniter. I inspected bulkhead and heat exchanger . I tested the 2mfd inducer run capacitor. I regulated gas pressures . I pulled amp draws on all mechanical components. I pulled temperature rise 45° . I cleared out condensate drain . ** I spoke to David regarding the 60 Amp (Non -Fused ) Disconnect . It Should be replaced prior to next Spring Service ( Pictures taken) . Quoted Customer


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Went to roof Cleaned electric compartment Checked all wiring, good Checked temperature rise rated 30-50 Low fire Supply 108 Return 74 Rise of 34,good High fire Supply 128 Return 84 Rise of 44,good Checked safety's, good Unit running as per manufacturer's specifications


Alexandra  C.

Alexandra C. Job Checkin

I checked in with the Miller's. Mrs. Miller requested I leave the 20x25x1 pleated filter with her ( She'll change it ). I set up my ladder and equipment. I cleaned out the control cabinet . I blew out ( mini leaf blower ) the control cabinet . I cleaned off flame sensor electrode. I inspected the Hot Surface igniter. I inspected the bulkhead and heat exchanger. I removed and cleaned burners. I tested all safety switches and controls . I tested the 55/5 mfd dual run cap .( 53.6/ 5.1) Temp rise is recommended between 35°-55° my actual is 74° return 120° Supply = 46° . I pulled amp draws on all mechanical components. I regulated gas pressures from 3.74- 3.25inw.c. The unit is operating at factory recommended specifications at this time.


Alexandra  C.

Alexandra C. Job Checkin

checked in with Gary cleaned burners cleaned off flame sensor electrode. checked outlet gas pressure regulated gas pressures to 3.25 inw.c. Newly installed 20x25x1 pleated filter pulled amp draws pulled temp rise 73/116 = 47° inspected bulkhead and heat exchanger The furnace is operating at factory recommended specifications at this time


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Replaced filters Went to closet Cleaned electric compartment and closet platform Checked all wiring, good Checked for proper sequence of operations, good Checked temperature rise rate 25-55 Supply air 107 Return air 72 Rise of 35,good Units are running per manufacturer specifications


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Replaced the three filters Went to attic Checked all wiring, good Went to check temperature rise, but unit is tripping out on high limit switch Asked resident if they wanted me to troubleshoot issues Resident declined to troubleshoot issue Job Complete at this time


Alexandra  C.

Alexandra C. Job Checkin

Checked in with Customers. Cleaned out control cabinet. Cleaned off flame sensor electrode. Inspected Hot Surface Igniter . Removed and cleaned burners. checked natural gas outlet pressure ( 3.4 inw.c.) Pulled amp draws on all mechanical components. Inspected bulkhead and heat exchanger. Pulled temperature rise 77° return 127°supply = 50° TR . The unit is operating at factory recommended specifications at this time. Job Complete


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Went to roof Cleaned electric compartment Checked all wiring, good Checked heat exchanger, good Checked temperature rise rated 30-60 Supply air was 156 Return air was 74 Rise of 82, way to high Adjusted gas valve Supply air 130 Return air 80 Rise of 50,good Checked safety's, good Returned another day to deliver filters


Alexandra  C.

Alexandra C. Job Checkin

*****TEST*****


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Went to garage Cleaned electric compartment Checked all wiring, good Found bad capacitor for blower motor Replaced 10uf Checked temperature rise Supply air 96 Return air 74 Rise of 22,good Unit now running per manufacturer specifications


Alexandra  C.

Alexandra C. Job Checkin

Contacted resident Left filters with resident as per request Went to attic Fan coil unit 1 Cleaned electric compartment Checked all wiring, good Checked for proper sequence of operations, good Checked temperature rise Supply air 105 Return air 70 Rise of 30,good Went to fan coil unit 2 Cleaned electric compartment Checked all wiring, good Checked for proper sequence of operations, good Checked temperature rise Supply air 116 Return air 78 Rise of 38,good Checked water heater Water supply set point 140 Set to an 8°differential Water cycled on and off properly when fan coil units where in operation


Alexandra  C.

Alexandra C. Job Checkin

I checked in with Tina . I inspected the Thermostat. I replaced the 20x25x1 pleated filters. I set up my ladder and equipment. I removed and cleaned burners. I cleaned off the flame sensor/ Spark electrode. I regulated gas pressures . I cleaned out the inducer vacuum port . I checked all safety and controls . I pulled amp draws on all mechanical components. I tested the 2 mfd run cap which is still in range. 44 ° temp rise 75 ° return / 119 ° supply . The unit is operating at factory recommended specifications at this time.