I am very satisfied with the service from Rare Service Heating & Air Conditioning appointment was fast and they offer great price.
Response from Rare Service Heating & Air Conditioning, INC:
Elyse, Thank you for choosing us to be your service provider. We are happy to hear that you are satisfied with the service your received. Rare Service
Great serviceThis is the second time David has come to my house and he’s efficient and polite
Came and fixed it quickly.
Response from Rare Service Heating & Air Conditioning, INC:
Thank you for your response Sherril. We are happy to be your service provider. Rare Service
Great service and I trust the work done. Very reliable company.
Response from Rare Service Heating & Air Conditioning, INC:
Diane, We are very happy to hear that you were pleased with our work. Thank you for allowing us to be your service provider. Rare Service
My technician was very professional and made sure I understood what he was doing.
Response from Rare Service Heating & Air Conditioning, INC:
Alfredo, We are pleased to hear that you were happy with our technician! Thank you for your feedback. It is a pleasure to be your service provider. Rare Service
My service technician reviewed my unit thoroughly and cleaned additional parts due to wear and build up over time. I was very impressed with his attentiveness to keep me updated and make sure everything was running well.
I love your service. I am so glad I signed up for twice yearly check ups. Nice to know my unit is running well. It seems to run cheaper too.
Great AC/heater inspection and report for house in escrow. Tim explained everything in detail. Will use for service!
Rare did a great job of staying in communication with me and keeping me updated on their progress. I highly recommend them.
Contacted resident Replaced filter Went to attic Cleaned electric compartment Cleaned condensate line Checked all wiring, good Checked temperature split Supply air 52 Return air 74 Split of 22, good Went outside to condenser unit Cleaned electric compartment Cleaned condenser coil Checked all wiring, good Compressor amps 12.4, rated 19.2, good Condenser amps 1.9, rated 2.5, good Dual capacitor (turbo) 60+5 Herm 59 Fan 5.4 Unit running as per manufacturer's specifications Had resident fill out five star paperwork Collected $234.00 by phone with credit card
Contacted resident Resident stated that the filter is good Went to attic Cleaned electric compartment No access to clean condensate line Checked all wiring, good Checked temperature split Supply air 50 Return air 70 Split of 20, good Compressor amps 7.3, rated 13, good Condenser amps 1.2, rated 1.5, good Dual capacitor 45+5 Herm 46.5 Fan 5.1 Unit is running as per manufacturer's specifications
Checked in with Roger . Replaced the 20x30x1 pleated return filter. Inspected the Thermostat . Tested the 60/5 dual mfd run capacitor. Inspected the 240v Contactor. Pulled amp draws. Checked refrigerant charge. Vacuumed out condensate drain line. Removed leaves out from interior side of Condenser. Washed out Condenser coil inside & out . Pulled temp split differential. The unit is operating at factory recommended specifications at this time.
Contacted resident Discussed residents concerns Found drain plugged Blew drain out from PVC pipe connection and back to evap head Draining properly now
Contacted resident Replaced filters Went to roof Cleaned electric compartment Cleaned condenser coil Cleaned condensate lines Checked all wiring, good Checked temperature split Supply air 50 Return air 70 Split of 20, good Compressor amps 6.9, rated 14.1, good Condenser amps 1.0, rated 1.5, good Dual capacitor 45+5 Herm 43.9 Fan 4.8 Unit running as per manufacturer's specifications Job Complete
Contacted resident Replaced filter Went to roof Cleaned electric compartment Cleaned condenser coil Cleaned condensate line Checked all wiring, good Checked temperature split Supply air 51 Return air 69 Split of 18, good Compressor amps 10.1, rated 25.6, good Condenser amps 1.4, rated 2.0, good Capacitors 1)40, 1) 10 Herm 233, bad Fan 8.4, bad Recommend replacing capacitors (replaced on another work order) Unit running as per manufacturer's specifications Job Complete
Contacted resident Left filter with resident Went to roof Cleaned electric compartment Checked all wiring, good Checked temperature split Supply air 42 Return air 61 Split of 19,good Compressor amps 8.4 rated 15.4 Condenser amps 1.0 rated 1.2 Dual cap 50+5 Herm 48.4, good Fan 5, good Unit running as per manufacturer's specifications
Picked up filters . Checked in with Michael . Replaced return filter . Inspected Thermostat. Climbed up to attic . Removed and washed air purifier filters . Dried out filters prior to setting back into place Tested 45/5 dual run capacitor. Pulled amp draws . Checked refrigerant charge (410A) Suction psi - 105 / 20.6 ° SH. High Side. 176.5/ 7.1° Sub-Colling Washed Condenser coils . The system is operating at factory recommended specifications .
Checked in with Customers. Cleaned out control cabinet. Tested the dual run capacitor. Pulled amp draws. Sub- cooling 8.9° degrees. Refrigerant charge high side 210 Suction. 64.6 . Washed Condenser coil . The unit is operating at factory recommended specifications.
Checked in with Customers. Cleaned out control cabinet. Tested the dual run capacitor. Pulled amp draws. Sub- cooling 8.9° degrees. Refrigerant charge high side 210 Suction. 64.6 . Washed Condenser coil . The unit is operating at factory recommended specifications.
Contacted resident by phone Went to roof Removed bad relay Installed new relay Checked for proper operation Fan cycling on as per manufacturer's specifications Job Complete
Checked in with Customer . Located the hall closet furnace. During diagnostic testing found HSI @ 45° angle causing delayed combustion tripping rollout switch. Inspected heat exchanger to ensure no leaks. Cleaned off flame sensor electrode. Tighten down the HSI in its correct position . Checked controls and safety switches . Inspected inducer Motor . Pulled amp draws on all mechanical devices. Pulled temperature split differentials. 74 RA / 115 SA = 39° TR. The unit is operating at factory recommended specifications at this time. Shawlene approved 5 Star Maintenance Agreement .
Contacted resident Replaced two 20x25x1 filters Went to attic Cleaned electric compartment Checked all wiring, good Checked heat exchanger, good Checked temperature rise rated 35-65 Supply air 125 Return air 72 Rise of 53,good Checked safety's, good Unit running as per manufacturer's specifications
Contacted resident Went to roof Cleaned electric compartment Checked heat exchanger, good Checked temperature rise rated 20-50 Supply air 102 Return air 71 Rise of 31,good Checked safety's, good Unit is running as per manufacturer's specifications
Contacted resident Went to basement Replaced bad limit switch Ran unit Cycled unit three times Unit running as per manufacturer's specifications