207 E. Los Feliz Rd
Glendale, CA 91205
(800) 273-7710

Local Reviews
for wasco, ca

Rated 5.0 out of 5 stars based on 3 customer reviews

Great service

Very dependable. Always a fast response when we call.


Response from RESSAC Climate Control:

Hi Yesenia, thank you so much for the review. We're glad to be a vendor you can depend upon when you need help ASAP!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service !

The experience was professional and very helpful


Response from RESSAC Climate Control:

Glad we could help Adam!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Professional


Response from RESSAC Climate Control:

That's awesome, thanks for the feedback Adam!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wasco, ca

Jesus  A.

Jesus A. Job Checkin

A commercial customer reported that their grab and go cooler had gone out and was no longer working in Kern County California. Upon arrival, the technician had to thoroughly clean the evaporator coils as they were dirty and then troubleshooted the system. Found the controller overheating, removed some of the insulating tape to test and adjusted position for better ventilation. Controller may need to be replaced, recommend monitoring operations as system is working at this time.

A commercial customer reported that their grab and go cooler had gone out and was no longer working in Kern County California. Upon arrival, the technician had to thoroughly clean the evaporator coils as they were dirty and then troubleshooted the system. Found the controller overheating, removed some of the insulating tape to test and adjusted position for better ventilation. Controller may need to be replaced, recommend monitoring operations as system is working at this time.

Jesus  A.

Jesus A. Job Checkin

Received a report about a commercial ice cream forming icicles inside and also on the product in Wasco CA. After checking in with the store manager, our refrigeration tech inspected the problem unit, finding that both the defrost termination and heater limit switches had failed, causing the excess droplets to form and freeze. Removed defective parts, sourced replacements from local part house and returned to put new ones in. Ran and cycled unit, tested operations after repairs. Freezer working normally now, holding negative temperatures and water dripping.

Received a report about a commercial ice cream forming icicles inside and also on the product in Wasco CA. After checking in with the store manager, our refrigeration tech inspected the problem unit, finding that both the defrost termination and heater limit switches had failed, causing the excess droplets to form and freeze. Removed defective parts, sourced replacements from local part house and returned to put new ones in. Ran and cycled unit, tested operations after repairs. Freezer working normally now, holding negative temperatures and water dripping.

Jarred S.

Jarred S. Job Checkin

A second repair was scheduled today for a pharmacy in Wasco California. Their #1 roof top air conditioner had a bad compressor contactor. After wiring in the new contactor and testing the system, the technician confirmed the commercial York unit was operational again and cooling as expected. Job complete.

A second repair was scheduled today for a pharmacy in Wasco California. Their #1 roof top air conditioner had a bad compressor contactor. After wiring in the new contactor and testing the system, the technician confirmed the commercial York unit was operational again and cooling as expected. Job complete.

Jarred S.

Jarred S. Job Checkin

Our Wasco CA area technician returned to a pharmacy to performed approved repairs on their commercial Turbo Air cooler. The system has a faulty temperature control that was found on the last PM. After completing repairs, the tech ran and tested the unit to confirm it was operational again. Cooler at operating temperatures and no more issues to report.

Our Wasco CA area technician returned to a pharmacy to performed approved repairs on their commercial Turbo Air cooler. The system has a faulty temperature control that was found on the last PM. After completing repairs, the tech ran and tested the unit to confirm it was operational again. Cooler at operating temperatures and no more issues to report.

Jesus  A.

Jesus A. Job Checkin

RESSAC technician performed quoted work at a Wasco, California, pharmacy, installing two new lids and new temperature control on their hand dip freezer. Tested and adjusted controller after instillation to make ice cream softer to scoop for employees, but still frozen. No other issue to report, 2nd hand dip with similar issues will be repaired on separate PO#.

RESSAC technician performed quoted work at a Wasco, California, pharmacy, installing two new lids and new temperature control on their hand dip freezer. Tested and adjusted controller after instillation to make ice cream softer to scoop for employees, but still frozen. No other issue to report, 2nd hand dip with similar issues will be repaired on separate PO#.

Francisco R.

Francisco R. Job Checkin

RESSAC refrigeration tech returned to a Wasco, CA, pharmacy chain to complete quoted repairs. The walk-in freezer Masterbilt condenser unit had a failed compressor contactor that needed to be replaced. The technician also added oil to correct levels. Tested system, waited for unit to reach appropriate temperatures. No more issues found, walk-in working well.

RESSAC refrigeration tech returned to a Wasco, CA, pharmacy chain to complete quoted repairs. The walk-in freezer Masterbilt condenser unit had a failed compressor contactor that needed to be replaced. The technician also added oil to correct levels. Tested system, waited for unit to reach appropriate temperatures. No more issues found, walk-in working well.

Francisco R.

Francisco R. Job Checkin

RESSAC refrigeration tech responded to a leaking grab and go dairy case in Wasco, California. After inspecting the Turbo Air cooler, found a crack in the drain line. New drain kit from the factory would need to be ordered. Was able to source a temporary replacement section locally and splice in a drain section to stop water leaking, for now. Reported back to office with findings, will quote to customer for special-order kit.

RESSAC refrigeration tech responded to a leaking grab and go dairy case in Wasco, California. After inspecting the Turbo Air cooler, found a crack in the drain line. New drain kit from the factory would need to be ordered. Was able to source a temporary replacement section locally and splice in a drain section to stop water leaking, for now. Reported back to office with findings, will quote to customer for special-order kit.

Pete N.

Pete N. Job Checkin

RESSAC A/C technician received call for commercial service at drug store in Wasco, California. Tech found communication panel unplugged and he plugged it back in. He started up the unit and found that all communication with the communication system was good.

RESSAC A/C technician received call for commercial service at drug store in Wasco, California. Tech found communication panel unplugged and he plugged it back in. He started up the unit and found that all communication with the communication system was good.