I wanted to thank you RT Olson team, Especially David and Jr for doing a great job of replacing a new pipeline.
Tuneup the ac system and evaluated and diagnosed the efficiency and integrity of the design. Key concerns: Evaporator coil is showing signs of biological growth inside the drain pan where the dust has accumulated, and the moisture has created a bond Air-conditioning system is filled with R 22 refrigerant that has been obsolete since 2020 and the outdoor unit has microchannel aluminum coils, which is the cheapest and most prone to leaks. Also, the dogs have been peeing on one side of it which is going to cause the aluminum to thin out from the acidity of the pee Airflow is poor to daughter‘s room due to the fact of the ducting design where it is losing pressure because it is the last run on a trunk Attic insulation is so low it’s less than 4 inches which is what it used to be in the 70s. The current attic insulation for 2025 is 13 inches thick and these newer systems are rated for homes that are designed with the correct and proper amount of insulation to cool the home efficientl
Customer complained that after taking a shower the wall and carpet was wet. We came out and tested the shower valve. When the water was on the water flowed back into the wall causing sudden and accidental water damage.
Located burst water line under the bathtub. Claim # 0742341324 Josie Schmitt 815-888-2817 claims@claims.allstate.com
Customer complaint of burst water pipe after new water heater install Technician found water heater plumbing supply flooding out of the ceiling Recommend access ceiling for possible repair Tech demolished ceiling near water heater supply. - tech found 3/4 CPVC Cold tee snapped off directly above exposed push to connect “shark bite “ fitting. - Most likely caused by lack of drywall access when installing push to connect fitting adapting to new ball valve for water heater install - leak appears to have been discovered within 24 hours of occurrence Tech recommended reset water heater due to close quarters repair needed above wall (for dining room/ garage - behind water heater ) Tech will remove water heater Repair pipe segment on cpvc in garage ceiling Reinstall ball valve Reinstall water heater Estimate does not include water damage repairs or drywall Reinstalling customer supplied water heater only All systems functioning as designed no leaks. 3/29
Burst water line rolls under both showers from one bathroom manifold to the other. We are recommending to reroute the pipe instead of breaching through the bathtub.
Shower valve leak cartridge omen delta drywall repair