3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for blacklick, oh

Rated 5.0 out of 5 stars based on 2 customer reviews

Awesome and dependable

I always use sears heating and cooling. They are honest helpful polite professional and I trust them. Wally was great and helpful yoday


Response from Sears Heating & Cooling:

Thank you for the great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service!

Technician thankfully arrived early in the 5 hr window and was here maybe 1/2 hr. Of course today wasn't the kind of day you want to test your A/C, but I look forward to being able to use it as soon as temperatures rise!


Response from Sears Heating & Cooling:

Thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for blacklick, oh

Austin L.

Austin L. Job Checkin

Conducted an air conditioner check on a 2017 Lennox air conditioner. All electrical and mechanical components of the system check out at this time. During testing of the unit the technician found no electrical protection device for outdoor unit. Technician presented options HB7 a-e. Customer declined at this time. Technician left customer information pamphlet regarding our service club program. Customer stated she will talk it over with her husband and will call the office if deciding to move forward with joining the club.


Austin L.

Austin L. Job Checkin

Conducted a furnace check on a 2017 Lennox furnace. All electrical and mechanical components of the system check out at this time. Technician found no electrical protection device for the furnace. Technician presented options HB7a-e. Customer declined at this time.


Jamie S.

Jamie S. Job Checkin

Gave cost to replace heat pump with air conditioning. Cost to install two stage American Standard air conditioner

Gave cost to replace heat pump with air conditioning. Cost to install two stage American Standard air conditioner

Ramon R.

Ramon R. Job Checkin

Performed air conditioner maintenance and safety check on Bryant unit


Austin L.

Austin L. Job Checkin

Technician responded to a no cool situation on a 2019 Goodman air conditioner. Upon testing of the unit the technician found the voltage enhancement system to be completely drained. The customer stated they had a power outage last night. The technician also found the outdoor unit to be very dirty on all sides. Technician presented options Hn13a-e. Customer chose option B and declined a cleaning stating they would take care of that themselves. Technician verified operation of the system after repair was completed. Supply air 59. Return air 81. No issues at this time.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2010 Goodman air conditioner. All mechanical components of the system check out at this time. During testing of the unit the technician observed the initial amp draw to be outside of manufactures specifications, As well as the voltage enhancement system well out of manufactures specifications. Technician also recommend adding a surge protector for the outdoor unit. Technician presented options hn13 a-e. Customer stated they will speak it over with their significant other and call the office back to set up a future repair time.


Austin L.

Austin L. Job Checkin

Technician responded to a insufficient cooling call on a 2020 Goodman air conditioner. Technician verified all electrical and mechanical components of the system were working properly. Technician hooked up gauges And verified the charge level was that manufactures specifications. Technician took a temperature measurement and the house had a 19° temperature split. Technician presented options for a thermostat repair, customer stated they will take care of that themselves and if there are any further issues they would call us back out.


Joel  T.

Joel T. Job Checkin

Ac maintenance inspection.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2016 Bryant air conditioner. All mechanical components of the system check out at this time. During testing of the unit the technician observed the initial amp draw of the compressor just within manufacture specifications. Technician presented options Hn1a-e. Customer stated that because the reading was still within manufacture specifications that she wanted to re-address the situation come spring.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2016 Bryant air conditioner. All mechanical components of the system check out at this time. During testing of the unit the technician observed the initial amp draw of the compressor just within manufacture specifications. Technician presented options Hn1a-e. Customer stated that because the reading was still within manufacture specifications that she wanted to re-address the situation come spring.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2011 Bryant air conditioner. All mechanical components of the system check out at this time. During testing of the unit the technician observed a voltage enhancement system outside of the manufacturers specifications. Technician present adoptions HN13 a-e. Customer decided to decline any repair option at this time.


Wally T.

Wally T. Job Checkin

Replaced discharged capacitor on a Bryant air conditioner


Robby D.

Robby D. Job Checkin

Found customer had aquatherm furnace. Found drain pain has layer of sut and clogged drain pain. Offered Ho1a to replace short drain. Customer accepted. Performed repair and purged drain line. No further concerns at this time


Robby D.

Robby D. Job Checkin

Upon arrival made call for cooling found indoor systems cycled on outdoor system had failed found voltage absorption system swollen and dead presented options HN13A-E. Customer chose option e. Performed repair and cycled unit. Found blower motor shorted. Called for pricing and availability. Covered under option E for customer per office! Completed repair and cycled unit. System running with 20 degree temperature drop.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2016 Bryant air conditioning system unit is running properly and within manufacture specifications at this time. No concerns