3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for blacklick, oh

Rated 5.0 out of 5 stars based on 2 customer reviews

Awesome and dependable

I always use sears heating and cooling. They are honest helpful polite professional and I trust them. Wally was great and helpful yoday


Response from Sears Heating & Cooling:

Thank you for the great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service!

Technician thankfully arrived early in the 5 hr window and was here maybe 1/2 hr. Of course today wasn't the kind of day you want to test your A/C, but I look forward to being able to use it as soon as temperatures rise!


Response from Sears Heating & Cooling:

Thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for blacklick, oh

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2020 Bryant air conditioning system. Found 40/5 voltage absorbed in system reading 40/5. 103.5 in Rush amps. Informed customer of surge protection customer will keep it in mind found 213 filter clean replaced last month. No issues found at this time


Jamie S.

Jamie S. Job Checkin

Cost to install hot water tank and furnace

Cost to install hot water tank and furnace

Jamie S.

Jamie S. Job Checkin

Cost to replace furnace. Cost to install Bryant furnace.

Cost to replace furnace. Cost to install Bryant furnace.

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2020 Goodman unit. Left new 1625 one filter. Found 45/5 voltage absorbs in system reading 44.5/5. 53 in Rush amps. No issues found at this point in time


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant AC system found 40/5 orange absorption system reading 38.4/4.9. 84.9 inrush amps. Replaced 14201 filter. No issues found.


Robby D.

Robby D. Job Checkin

Upon arrival thermostat in off position. Made call for heat. Furnace cycled on properly. Ran with 10.8%o2. 11 ppm co in flu. 0 ppm co in supply. Furnace faulted on limit. Found filter to be in backwards. Found white particulate on filter consistent with room humidifier. Customer has humidifier in child’s bedroom. Room has independent returns.


Robby D.

Robby D. Job Checkin

Upon arrival furnace in lockout. Clean filter. Reset furnace furnace failed to cycle first attempt. Upon second attempt furnace cycled on properly. Cycled furnace multiple times. Furnace failed to fault while present. Advised can quote for board or inducer as inducer still has noise issues. Customer wanting to get by this year and replace come fall Wanted ballpark numbers for new furnace as current furnace is in operation. Ballparked 4500-7000 for 80% and 5000-7500 for 90%. Furnace running upon departure.


Joel  T.

Joel T. Job Checkin

Ac check


Wally T.

Wally T. Job Checkin

Replaced failed flame sensor on a Bryant furnace


Robby D.

Robby D. Job Checkin

Upon arrival customer closed technician noise recorded on phone. Found inducer noise upon start up. Excess noise detected but In working order. Blower motor Almost seized up completely. Extreme noise upon slow startup. After startup motor failed into stationary position. Called for pricing. In stock. Presented hc6 and hm9 to customer to address concerns. Customer chose option a for both repairs. Retrieved parts and performed repair. Cycled system 9.8%o2. 2 ppm co in flu 0 ppm co in supply. 50 degree dletat. No issues upon departure.


Ramon R.

Ramon R. Job Checkin

Completed routine furnace maintenance and safety check for a Bryant unit to ensure proper ventilation and combustion. Inspected all components for potential hazards and adjusted settings for optimal safety.


Robby D.

Robby D. Job Checkin

Made call for heat upon arrival. Inducer Motor making excess noise. Hm34a-e. Customer chose option a with 183 limited manufacture warranty credit. Retrieved part and performed repair. Motor sounds tremendously better. Furnace running with 12.2%o2. 7ppm co in flu. 0 ppm co in supply. No further concerns


Robby D.

Robby D. Job Checkin

Made call for heat upon arrival. Inducer Motor making excess noise. Hm34a-e. Customer chose option a with 183 limited manufacture warranty credit. Retrieved part and performed repair. Motor sounds tremendously better. Furnace running with 12.2%o2. 7ppm co in flu. 0 ppm co in supply. No further concerns


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2000s trane system. Upstairs unit in toy room. Found 11%o2 5ppm co in flu. 50 degree dletat. Lennox main system. 6%o2. 13 ppm co in flu. 57 degree deltat. Cleaned flame sensor replaced 213 filter. No issues at this time. Customer had technician look at fireplace, this is a standing pilot manual light fireplace. Gas supply present. No diagnosis possible no gas valve or Thermopile on system


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 98 Bryant furnace. Made call for heating. Furnace cycled on properly and running with 8.93%o2. 13 ppm. Co in flu. 0 ppm co in supply. 65 degree deltat. Inducer motor has excess vibration noise. 10 voltage absorption system reading 8.4 advised customer of findings due to age customer will wait on repair. No cracks in heat exchanger via pulling blower or limit hole