Response from Sears Heating & Cooling:
Thanks for the review!
Performed yearly maintenance and safety checks on 2010 Bryant air conditioner system. 35/5 voltage absorption system reading 33.7/4.8. 64 in rush amps. 88–108 hard start reading 105. Left 20251 filter. No issues at this time.
Rheem ac safety check and maintenance
Cost to replace air conditioning. Price to install AC.
Performed yearly maintenance and safety checks on 2013 Bryant AC system. Found 35/5 voltage absorbers in system reading 35/5 found 88–108 hard start reading 101. 58 in Rush amps informed customer of surge protection customer is not interested 16254 filter still has life customer maintains.
Found safety switch in primary drain, floor condensate drain in secondary. Swapped drains to proper outlets from drain pan. Found second water leak inside furnace drain clamp looks to be able to be better seated on trap. Fixed issue for customer no further issues at this time.
Cost to install heat pump system. Cost to replace electric heat pump with natural gas furnace and air conditioning.
Customer stated thermostat wasn’t reading indoor temp this morning. Thermostat reading 99 upon arrival. Explained options for replacement Quoted hh6 a-e customer chose option a retrieve t4 stat and performed repair. No issues upon departure. System running 0 ppm co in supply. Will have office send hard copy of invoice
Performed yearly maintenance and safety checks on 21 Bryant AC system. Found 40/5 option system reading 39.8/4.9. For 13 filter dirty in need of replacement, customer will maintenance filter themselves. 93 in rush amps. Cleaned condenser
Performed yearly maintenance and safety checks on 21 Bryant AC system. Found 40/5 option system reading 39.8/4.9. For 13 filter dirty in need of replacement, customer will maintenance filter themselves. 93 in rush amps. Cleaned condenser
Perform maintenance and service check on 2012 Rheem system Unit is operating properly at this time.
Perform maintenance and safety check on 2023 Bryant system
Performed maintenance and safety checks, checked voltage systems and air conditioning, found bacterial growth in evaporator coil Spoke about I wave Manufacturer date:: - 2013 Outdoor temperature:: - 54 Refrigerant type:: R-410a aka Puron Capacitor-455 actual 455 Start up amps-58 Fan amps-0.58 Hard start-105 Cleared condensate drain line- Checked reversing valve: Yes Checked Defrost timer: Yes Checked safety controls: Yes Temperature rise:: Return Air Temp: -n/a
Performed yearly maintenance and safety checks on 04 Bryant air conditioning system. Found low deltat. 13 degree. Found unit low on charge. 22 system. Explained to customer current industry situation with refrigerants. Hj2C for repair. Customer wants quote for new system. Left Bryant and Payne system options for customer customer will decide and contact when ready to move forward.