Josh did my annual check up on furnace and also installed a humidifier. Josh thoroughly explained humidifier operation and it’s effectiveness. Excellent service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and price !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great guy

Enjoyed talking Hvac with our sears rep!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for grove city, oh

Jamie S.

Jamie S. Job Checkin

Cost to install air condition and furnace. Cost to replace central air conditioning and furnace.

Cost to install air condition and furnace. Cost to replace central air conditioning and furnace.

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 American standard heat pump. Found unit running within manufacture specifications at this time with no concerns


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2013 Rheem heat pump system. Found black mold inside cabinet of air handler. Informed customer of hazard. Offered iwave system to help purify and kill mold. Customer declined at this time. Offered surge and performance enhancement devices. Customer isn’t interested in systems.


Wally T.

Wally T. Job Checkin

Annual maintenance check on a Payne air conditioner. Added start assist to reduce energy consumption and extend compressor lifetime


Josh S.

Josh S. Job Checkin

No cool on ac tempstar. Bad capacitor 35/5. Replaced and cleaned unit added tabs to supply

No cool on ac tempstar. Bad capacitor 35/5. Replaced and cleaned unit added tabs to supply

Robby D.

Robby D. Job Checkin

Responded to leaking water call. Found puddle of water on floor below fresh air run. Performed series of diagnostic steps to find fresh air damper working correctly. Air conditioner dehumidifying correctly. No signs of water damage or signs of water present above, on, or around fresh air run in question. Around walls or floor where puddle is present. No cause for concern that water coming from duct work. Couldn’t find where water coming from. Did happen to find high head pressure and sub cooling present in running conditions. Found outdoor unit has layer of debris covering coil. Informed customer of issue. Informed customer of maintenance agreement and checks. Customer chose to sign up today. Will call back in to schedule time to come complete SCAC.


Josh S.

Josh S. Job Checkin

Ac check,on comfortmaker 2020 system is running good 16-25-1 filter

Ac check,on comfortmaker 2020 system is running good 16-25-1 filter

Jamie S.

Jamie S. Job Checkin

Gave cost to replace furnace and air condition. Cost to install central air conditioning

Gave cost to replace furnace and air condition. Cost to install central air conditioning

Jamie S.

Jamie S. Job Checkin

Cost to install furnace and air conditioning. 0% interest

Cost to install furnace and air conditioning. 0% interest

Jamie S.

Jamie S. Job Checkin

Cost to install furnace and air conditioning. 0% interest


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2020 Heat pump system. System is running properly and within manufacture specifications at this time. No concerns at this time. Offered surge protection and hard start kit accessories. Customer isn’t interested at this time.


Jamie S.

Jamie S. Job Checkin

Game cost to replace central air conditioning


Robby D.

Robby D. Job Checkin

Performed yearly Maintenance and safety checks on 2015 air conditioning system. System is running properly and within manufacture specifications at this time. Found concern involving compressor inrush amps high. Informed customer and presented options hn1 a-e. Customer chose option a. performed install of accessory. Inrush amps before install read 59 after install reduced to 34. No other concerns at this time.


Josh S.

Josh S. Job Checkin

Frozen coil on Goodman unit

Frozen coil on Goodman unit

Wally T.

Wally T. Job Checkin

Replaced failed capacitor and start assist, cleaned unit to improve unit performance. Work performed on a Goodman air conditioner