Replaced failed capacitor on Carrier heat pump. Diagnosed high amperage draw causing cycling issues. Capacitor measured at 35 microfarads against 45 rating. Installed new 45/5 dual run capacitor. Recommended annual maintenance to prevent premature compressor failure during upcoming cooling season.
Cost to replace air conditioning. Cost to install furnace and air conditioning.
Existing heat pump, though sparks out of it. Cost to install new heat pump system.
Performed a seasonal maintenance check on a Carrier heat pump. Cleaned the outdoor coils, checked refrigerant pressures, and inspected the electrical connections. Tested the reversing valve and defrost controls to ensure proper operation during colder weather. Confirmed that the thermostat was functioning correctly. The system is now ready for efficient heating throughout the winter.
Performed yearly maintenance and safety checks on 2005 Bryant furnace 13.04% 47 ppm 52 degree deltat. Replaced 35 wp. 20254 filter. Cleaned flame sensor. Blew through trap. 53 ohm igntion system. No issues at this time.
Cost to replace furnace with high efficiency. Cost to install furnace and air conditioning. Cost to install a humidifier.
Performed yearly maintenance and safety checks on 2015 rheem furnace. 10 kw heat kit. 21A being pulled 20em /20hp/40aux heat rise. 40/7.5 voltage absorption system reading 40/7.6. Advised dust is starting to show on inside of return. Advised thinking about cleaning. Customer stated it's been about 5 years.
Performed yearly maintenance and safety checks on 2016 rheem furnace. Found unit running with 10.28% o2 18 ppm co in flu. 0 ppm co in supply. 43 degree deltat.
Responded to no cool found dead voltage absorption system. Quoted hn13 customer chose option b for upgraded part. Performed repair. Customer requested check refrigerant. No issues found. Unit running properly upon departure. 20 degree deltat.
Cost to replace air conditioning. Cost to replace insulated return air duct. Their cat tore up the existing return air
Responded to no cool. Customer said it froze up. They let thaw for 24 hours and now thermostat states waiting reading sensors. Customer replaced filter and stated it was very dirty. Believed to be reason for freezing. Found good pressure with low subcooling. Dirty condenser. Offered to clean unit. Stated they will wash unit. Found thermistor had bad connection at heat pump. Replaced wire nuts and ensured good connection. Thermostat reading 91. 86 ambient temperature with sensor in sunlight. Accurate reading on stat. Unit cycled on properly multiple times
Performed yearly maintenance and safety checks on 2015 Rheem heat pump air handler system. Replaced 1625 one filter. 72 in rush amps. 40/5 voltage absorption system reading 40/5. 71/50 19° temperature difference. No concerns at this time
Performed yearly maintenance and safety checks no concerns