Jamie S.

Jamie S. Job Checkin

Cost to install air conditioning and furnace. Air conditioning is squealing due to condenser fan motor bearings failing. Cost to replace air conditioning.

Cost to install air conditioning and furnace. Air conditioning is squealing due to condenser fan motor bearings failing. Cost to replace air conditioning.

Joel  T.

Joel T. Job Checkin

The customer reached out for HVAC leak repair when their system began making unusual noises and failing to maintain consistent temperatures. Upon inspection, I discovered a refrigerant leak near the condenser, which was causing the system to lose pressure and struggle to regulate the indoor climate. I repaired the leak, replaced any damaged seals, and recharged the refrigerant to the proper level. After running the system through several cycles, it was cooling and heating effectively again, ensuring the customer’s HVAC system was fully operational and running efficiently.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 04 Bryant furnace. Found humidifier  to not be in operation. Customer did not want repairs done on it. Replaced 16201 filter. Cleaned flame sensor and flu trap. Unit running with 9.75%o2. 33ppm co in flu. 0 ppm co in supply. 48 degree deltat. 10 voltage absorption  system reading 9.2.


Robby D.

Robby D. Job Checkin

Return to check on noise customer said he has not experienced vibration today noise happens at night. Ensured blower motor and wheel are tight and not moving. Ran heat pump in heating. Customer nor tech Experienced vibration noise. Ran in cooling,em heat, and tested defrost to find similar results. Covered today trip under repair. Advised will have to charge service charge if needing to return again.


Robby D.

Robby D. Job Checkin

Return to replace blower and wheel performs repair cycled on heat pump to ensure operation unit working properly at this time with no access noise


Robby D.

Robby D. Job Checkin

Return to replace blower and wheel performs repair cycled on heat pump to ensure operation unit working properly at this time with no access noise


Jamie S.

Jamie S. Job Checkin

Cost to install Central air conditioning.

Cost to install Central air conditioning.

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2007 Goodman air conditioning system found 40/5 voltage absorption system reading 39.9/5. Found condenser fan motor running high amps and has surface rust. Called for pricing. Quoted Hc8c-e. Customer denied repairs at this time and will prepare for issues Or to address concerns at a later date. Customer parents working in basement advised to replace filter 2-3 times as often to prevent buildup or inefficiency’s


Jamie S.

Jamie S. Job Checkin

Cost to install central air conditioning

Cost to install central air conditioning

Robby D.

Robby D. Job Checkin

Responded to no cool found fan and compressor capacitor completely dead. Presented options HN13A-e with $65 limited manufacture warranty credit. Customer chose option c to have upgraded absorption system and start assist added to system. Performed repair. Found loose low voltage wire. Secured connection. System running upon departure 74/54. 20 degree deltat. No issues at this time.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 23 Bryant air conditioning system. Found 35/5 voltage absorption system reading 34.9/4.9.. 74 inrush amps. No issues at this time. 51 degree ambient.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant air conditioning system. Found 40/5 old is absorbed in system reading 38.5/4.8. Cleaned condenser, left new 16251 filter. Informed customer of surge and start assist customer is not interested at this time


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant air conditioning system. Found 40/5 old is absorbed in system reading 38.5/4.8. Cleaned condenser, left new 16251 filter. Informed customer of surge and start assist customer is not interested at this time


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2023 Bryant AC system. Found 40/5 voltage absorption system reading 40/5. 84.3 inrush. No issues found at this time. Left new 16251 filter.


Robby D.

Robby D. Job Checkin

Responded to furnace issues. Customer stated filter only lasted about 3 weeks before furnace overheats. Found multiple closed registers on every floor of home. Opened all registers for maximum airflow. Filter is white and full of while particle matter typically associated with isolated room humidifiers. Customer uses humidifiers upstairs with baby advised to be sure to use distilled water specifically cannot check at this time as baby is in room being attended to. Customer chose to sign up for maintenance customer requested we start with ac check. Cycled furnace. Found steady running state of 32 degree deltat. Pushing 108 degree supply air.