Austin L.

Austin L. Job Checkin

Conducted annual maintenance on an unknown year Coleman Evcon air conditioner. All electrical and mechanical components of the system check out at this time. Technician spoke to customer about the age of the unit as well as the type of refrigerant it uses no longer being available. Customer stated he was aware and was waiting to get as much life out of the current unit as possible before buying a new one.


Austin L.

Austin L. Job Checkin

Responded to a no cool situation on a 2012 Bryant air conditioner. Upon testing of the system The technician found the voltage enhancement system was completely dead. Technician presented options Hn13a-e. Customer chose option B. Take Mission completed repair and verified operation of the unit. Supply air 55.8. Return air 72. Technician also recommended cleaning of the unit to witch the customer declined due to cleaning the unit himself. Customer did ask for information about the service plan, to which the customer left a pamphlet with the information.


Jamie S.

Jamie S. Job Checkin

Cost to install air condition and furnace. Cost to replace air condition that’s too small for the house

Cost to install air condition and furnace. Cost to replace air condition that’s too small for the house

Jamie S.

Jamie S. Job Checkin

Cost to replace air condition. Customer was told that he needs to put a new furnace in with the new air condition and that is not true.

Cost to replace air condition. Customer was told that he needs to put a new furnace in with the new air condition and that is not true.

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant air conditioning system. Unit is running properly and within manufacture specifications at this time. Unit is running with 18 degree delta t at 60 degree ambient temperatures. Voltage absorption system is rated 35/5 reading 34.7/4.9. Unit doesn’t have hard start or surge protection systems installed informed customer of accessories however customer isn’t interested due to planning on relocating in next couple years


Austin L.

Austin L. Job Checkin

Performed annual maintenance on a 2015 Goodman air conditioner. All mechanical components on the unit checked out at this time. Technician noticed voltage distribution system chattering as well as the amp draw being outside manufacturers specifications when testing. Technician presented options HD3 A-E. Customer chose option B. Four has been corrected and no other issues at this time.


Austin L.

Austin L. Job Checkin

Perform annual maintenance check on a Rheem air conditioner

Perform annual maintenance check on a Rheem air conditioner

Robby D.

Robby D. Job Checkin

Performed the yearly maintenance and safety checks on 2013 Bryant air conditioning system. Due to ambient temperature technician did not allow unit to run for extended periods of time, technician also could not get accurate temperature drop. Customer stated it was too cold outside to turn water supply on, customer understands and is okay with technician not cleaning coil. Coil is dirty with debris informed customer of finding and mentioned cleaning coil off when weather reaches more comfortable ambient temperatures. Found higher start up amps. Informed customer of hard start kit to help compressor load and attempt to extend compressor life. Presented options HN1 customer chose to pass at this time. Left new 16251 filter on filter rack. No further concerns at this time.


Robby D.

Robby D. Job Checkin

Performs yearly maintenance and safety checks on 2021 Bryant air conditioning system. System is running within manufacture specifications at this time with a 20° temperature drop capacitor rating 35/5 capacitor actual reading 35/5. No concerns at this time


Jamie S.

Jamie S. Job Checkin

Cost to install furnace and air condition.

Cost to install furnace and air condition.

Robby D.

Robby D. Job Checkin

Homeowner not present during second opinion visit. Son was present during visit. Son stated company came out yesterday for a no cool call. Company informed customer unit had bad compressor. Through diagnostic steps found that compressor does indeed run win disconnect is engaged. Fan motor on top does not start up. Cap rating 35/5 reading 34.8/4.9. Called for pricing and availability on motor. Presented options HC25A-E. son stated he will talk over with father can will call us back. Fins on unit look to be in declining condition.


Robby D.

Robby D. Job Checkin

Upon arrival thermostat set to heat position, customer stated just replaced filter. furnace has been running sporadically. Furnace was running without fault code at time of technician arrival, technicians cycled unit multiple times to attempt fault. No fault at this time furnace has been running for 14 min at this time without fault or concern. Temperature rise 41. 0 co in supply. Cycled into high fire properly ran for 5 min until tech satisfied thermostat. Ran unit for roughly 45 min without fault or concern. Cycled multiple times without failure stat satisfied at 70 before technician departure . Unit cycled down properly


Jamie S.

Jamie S. Job Checkin

Cost to replace furnace. Cost to install Bryant high-efficiency furnace.

Cost to replace furnace. Cost to install Bryant high-efficiency furnace.

Cody C.

Cody C. Job Checkin

Upon inspection found unit limit safety system had failed. Unit heat exchanger has a lot of rust rust and is starting to peel. Talk to customer about concerns. Customer would like an estimate on a new unit. Customer schedule of Jamie out later today to give an estimate. Upon departure unit is off at this time.


Cody C.

Cody C. Job Checkin

Furnace check on a 2018 Bryant furnace. Completed performance check, safety check, mechanical check. Everything is working properly at this time.