Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant air conditioning system. Found 40/5 old is absorbed in system reading 38.5/4.8. Cleaned condenser, left new 16251 filter. Informed customer of surge and start assist customer is not interested at this time


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 Bryant air conditioning system. Found 40/5 old is absorbed in system reading 38.5/4.8. Cleaned condenser, left new 16251 filter. Informed customer of surge and start assist customer is not interested at this time


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2023 Bryant AC system. Found 40/5 voltage absorption system reading 40/5. 84.3 inrush. No issues found at this time. Left new 16251 filter.


Robby D.

Robby D. Job Checkin

Responded to furnace issues. Customer stated filter only lasted about 3 weeks before furnace overheats. Found multiple closed registers on every floor of home. Opened all registers for maximum airflow. Filter is white and full of while particle matter typically associated with isolated room humidifiers. Customer uses humidifiers upstairs with baby advised to be sure to use distilled water specifically cannot check at this time as baby is in room being attended to. Customer chose to sign up for maintenance customer requested we start with ac check. Cycled furnace. Found steady running state of 32 degree deltat. Pushing 108 degree supply air.


Robby D.

Robby D. Job Checkin

Upon arrival found water leaking onto floor from return. Found water panel sucked into return. Customer opted to have pad replaced. Furnace coding 3. Pressure switch. Found inducer port clear removed flu to fine no obstruction. Found significant corrosion/rust on heat exchanger upon returning furnace to service found furnace firing up and running. Inducer motor has squealing and excess noise. Will call Tomorrow for pricing and Availability pressure switch and inducer motor. Left quote for full system for customer.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 18 Bryant furnace. Found 9% o2. 24 ppm co in flu. 56-degree deltat. 48 ohm ignition. Left new 16251 filter. No concerns at this time.


Wally T.

Wally T. Job Checkin

Annual maintenance check on a Bryant furnace


Wally T.

Wally T. Job Checkin

Annual maintenance heck on a Comfortmaker furnace


Wally T.

Wally T. Job Checkin

Replaced failed igniter and flame sensor on a Bryant furnace


Austin L.

Austin L. Job Checkin

Complete an annual maintenance on a 2004 Bryant furnace. During testing of the unit, the technician found no electrical protection device, as well as dirt beginning to form on air circulation system. Customer is not interested in repair options at this time. Technician showed customer how to operate current thermostat. Customer did not want any new thermostat due to level of difficulty to operate. Technician verified successful operation and drainage of humidification system, so humidity levels at 35%, and replaced 10wp. Technician verified. Customer has functional carbon monoxide detector. Technician left customer with business card if she has any issues or questions about thermostat again in the future.


Jamie S.

Jamie S. Job Checkin

Cost to install central air conditioning. Air conditioning compressor has failed price to install new.

Cost to install central air conditioning. Air conditioning compressor has failed price to install new.

Austin L.

Austin L. Job Checkin

No cool on an unknown year, make and model air conditioner. Initial inspection of the outdoor unit technician found multiple plants and thick limbs growing into and through the unit. Technician tried to cycle unit but was unsuccessful. Technician verified incoming voltage, and found compressor to have failed. Technician also found voltage distribution system to show signs of age/pitting, and the air circulation system to be leaking oil. Customer is aware of age and condition of unit and wanted quote for replacement. Jamie out later today per office. Technician collected $79 service charge.


Wally T.

Wally T. Job Checkin

Unit is low on refrigerant. Customer chose to replace system. We are installing a Bryant 114.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2019 American Standard air conditioner. All electrical, mechanical and safety components of the system check out at this time. Technician unable to clean outdoor unit as water source was broken. Customer will fix and call office back to clean or have it done during furnace check. No issues at time of departure.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a 2019 American Standard air conditioner. All electrical, mechanical and safety components of the system check out at this time. Technician unable to clean outdoor unit as water source was broken. Customer will fix and call office back to clean or have it done during furnace check. No issues at time of departure.