Existing furnace has a corroded flue pipe and circuitboard that is fried. Cost to install furnace. Return air also needs to be a little larger for 3 tons of cooling.

Existing furnace has a corroded flue pipe and circuitboard that is fried. Cost to install furnace. Return air also needs to be a little larger for 3 tons of cooling.

Joel  T.

Joel T. Job Checkin

Furnace maintenance inspection


Robby D.

Robby D. Job Checkin

Responded to no cool, found 40/5 voltage absorption system reading 40.6nf/4.7uf. Dead herm. Quoted hn13. Customer chose option c for upgraded part and surge protection. Retrieved parts. Performed repair. Cycled system. 20 degree deltat. 75/55. Clean 16251 filter. Merv 13. Customer asked about higher rated filter. Expained pros and cons. Customer will test out this winter and revert back to merv 8 if need be.


Robby D.

Robby D. Job Checkin

Responded to second opinion. Home is 1 year old. Customer is having comfortability issues upstairs. Currently 8 degree difference between upstairs and main level. Explained second levels commonly have comfort issues. Customer had concerns with unit sizing.. found 3.5t ac installed. Per customer home is 3000 sq ft. Advised unit slightly undersized. Also found 8x24 return duct. Advised also small for system, 10x24 or 12x24 would much better suit home and allow better airflow throughout home. Advised we can replaced 3.5 with 4 ton but concerns still present with total comfortability upstairs. Customer has eco bee with smart sensor. Explained use of sensor and it’s pros and cons of use. Advised mini split would be most guaranteed route for proper comfort. Left quote for 3 head multi zone system. Customer is to talk with significant other and contact us to proceed.


Joel  T.

Joel T. Job Checkin

Ac maintenance


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on old air conditioning system could not find data plate or age of system, Qyntel system is R 22 system. Found multiple concerns including disconnect box fell apart upon attempting to remove disconnect coded HB7 for replacement disconnect. Customer chose option a. Replaced part. Cleaned system. 30/3 voltage absorption system reading 28.8/2.9. 17 degree deltat. Customer had mouse nest in ac. Cleared nest. Advised may want rodent deterrent to prevent damage. Corner of ac is missing fins advised typically associated with animal urine and to break any animal peeing on system.


Jamie S.

Jamie S. Job Checkin

Cost to install air conditioning. Bryce to install furnace and replace air condition.

Cost to install air conditioning. Bryce to install furnace and replace air condition.

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 21 Bryant ac system. Found 60 voltage absorption system reading 58.8. Advised bushes could be trimmed back to allow better airflow. Drier vent behind bushes has allowed condenser to be very dirty. Advised customer should keep up on maintenance and possibly think about a second wash down a year. Trimming bushes may also help unit stay clean. Advised customer of surge protection and hard start accessories. Ballparked 350 for one or 550 for both. Customer will talk with husband and call back if wanting to proceed


Robby D.

Robby D. Job Checkin

Responded to no cool. Made call for cooling. Found fan cycled on compressor failed to start. 60/5 reading 11/4.5. Quoted hn13 b-e. Customer chose option b. Performed repair and cycled system. System running with 20 degree deltat. 74/54 Informed customer of service club. Customer is not interested at this time. Clean AA 510 filter.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance safety checks on 2020 Carrier Air conditioning system. Found 60/5 voltage absorption system readings 58.8/5. 116inrush amps. Customer is not interested in surge protection at this time. 68/50. 18 degree deltat.


Robby D.

Robby D. Job Checkin

Returned to replace coil under warranty replaced coil unit running with 13° sub cool 12° superheat 18° delta T everything running properly and how it should at this point


Jamie S.

Jamie S. Job Checkin

Cost to install air conditioning. Cost to install natural gas furnace with air conditioning. Cost to replace natural gas furnace with heat pump system.

Cost to install air conditioning. Cost to install natural gas furnace with air conditioning. Cost to replace natural gas furnace with heat pump system.

Robby D.

Robby D. Job Checkin

Customer stated she would set thermostat to heat the furnace would not come on. May call for heat. Furnace cycled on properly multiple times without fault clean 14251 filter in 16251 rack. Advised will want to replace asap. Customer inquired if cooling worked made call. System cycled on properly. No issues at this time. Old Lennox furnace


Robby D.

Robby D. Job Checkin

System low on refrigerant. Leak in evap coil. Went over options left quote for 4 ton. QuotedHL2a-e for repair. Customer chose repair. Will have office call Monday to schedule.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 Bryant air-conditioning system. Found hinges to disconnect door off technician fixed door. Cleaned condenser left new 16251 filter. 69/49 20 degree deltat. 60 degree ambient temperature. No issues at this time. Customer not interested in surge protection as he recently found out he will be moving soon