Robby D.

Robby D. Job Checkin

Customer stated she would set thermostat to heat the furnace would not come on. May call for heat. Furnace cycled on properly multiple times without fault clean 14251 filter in 16251 rack. Advised will want to replace asap. Customer inquired if cooling worked made call. System cycled on properly. No issues at this time. Old Lennox furnace


Robby D.

Robby D. Job Checkin

System low on refrigerant. Leak in evap coil. Went over options left quote for 4 ton. QuotedHL2a-e for repair. Customer chose repair. Will have office call Monday to schedule.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 Bryant air-conditioning system. Found hinges to disconnect door off technician fixed door. Cleaned condenser left new 16251 filter. 69/49 20 degree deltat. 60 degree ambient temperature. No issues at this time. Customer not interested in surge protection as he recently found out he will be moving soon


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2017 Lennox ac system. Found 40/5 voltage absorption system reading 40/5. 73 in Rush amps. Cleaned condenser left new 20251 filter. 73/53 20 degree deltat. No issues found at this time.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2020 Bryant ac system. 35/5 voltage absorption system reading 35/5. 73 inrush amps. Clean 413 filter. Cleaned condenser. No issues.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 22 Bryant AC system. Found 35/5 voltage absorption system reading 34.3/4.9. 71 in Rush amps. No issues at this time. Cleaned condenser left new 16251 filter.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2021 Bryant AC system. Found 70/7.5 voltage absorption system reading 69.9/7.4. Cleaned condenser replace 2025 one filter no issues at this time added drain tabs


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 06 ac. 10 voltage absorption system reading 8.5. Blower wheel slightly dirty. Not impacted however. Cleaned condenser. Found 40/5 voltage absorption system reading 40/4.9. 96 inrush amps. Presented options HN10A to customer. Customer chose option a. Performed repair. Furnace running upon departure. Left new 20251 filter.


Robby D.

Robby D. Job Checkin

Before departure customer called back and said door didn’t seem shut. He pushed door in and unit lit and cycled on. Customer has concerns wants someone to check to see if doors need adjusted.. advised office will call in morning to schedule to have doors looked at.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2012 Bryant furnace. Found no sign of gas leak via electronic detector. 11% o2 8 ppm co in flu 0 ppm co in supply. Found significant rust in furnace. Customer does not recall being informed this before. Flu pipe runs over finished ceiling possibly leading to condescending draining into furnace. Customer will let go due to age of furnace and expecting replacement in next couple years. No further concer s


Robby D.

Robby D. Job Checkin

Performed dyealry maintenance and safety checks on Lennox 90% furnace. Found furnace running with 7.8% o2 9 ppm o in flu. 0 in supply. Found leak in gas line. Confirmed with bubbles. Presented leak to customer repair option HR4. Customer chose option a. Performed repair tested with electronic leak detector and double checked with bubbles with customer to ensure customer satisfaction. No sign of leak at this time 75 RA 137 SA 62 degree delta t. Offered to replace humidifier panel. Customer was instructed to turn off in winter and on in summer. Advised that is not accurate. Humidifier is needed in winter to add moisture content to the air. No further concerns at this time. Assigned to: Robby


Robby D.

Robby D. Job Checkin

Responded to no cool situation on 2020 system. Found 35/5 voltage absorption system reading 3.2nf/4.8. Presented hn13 a-e with option a being covered under full parts and labor. Customer chose option b to have upgraded voltage absorption system installed. 413 filter could be replaced customer accepted 84 for replacement filter. .. performed yearly maintenance and safety checks on 2020 Bryant furnace. 79RA 119 SA. 40 degree delta t.14 ppm co in flu. 0 ppm co in supply. No concerns at this point in time.


Jamie S.

Jamie S. Job Checkin

Cost to install furnace and central air conditioning. Cost to install I wave

Cost to install furnace and central air conditioning. Cost to install I wave

Austin L.

Austin L. Job Checkin

Technician back to complete repairs. Technician verified. Successful alignment and operation of the air circulation system after repairs were complete. Technician recommended blower wheel cleaning or replacement again due to amount of dirt build up. 19° temperature split a time of departure. No issues at time of departure.


Austin L.

Austin L. Job Checkin

Technician back to complete repairs. Technician verified. Successful alignment and operation of the air circulation system after repairs were complete. Technician recommended blower wheel cleaning or replacement again due to amount of dirt build up. 19° temperature split a time of departure. No issues at time of departure.