3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for reynoldsburg, oh

Rated 5.0 out of 5 stars based on 1 customer reviews

Great service

Joel showed up on time and took care of my air conditioner. He told me there was a problem and got it fixed up fast. The unit is working well right now.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for reynoldsburg, oh

Robby D.

Robby D. Job Checkin

Responded to no cool situation. Resupply power to unit customer stated breaker would trip immediately found breaker would trip immediately for 4 attempts. Breaker stayed on for 5th attempt. Found short at disconnect box high voltage rubbed through to metal. Older unit owner believes it’s original to home roughly 2009. No data plate legible. Hb5a-e. Due to age and cannot order parts cust9mer chose option a. Retrieved parts and performed repair. 20 degree deltat. 68/48. No issues at this time


Robby D.

Robby D. Job Checkin

Due to tornado watch in area advised customer we would reach out to schedule tomorrow. She will be home at 415 Upon arrival customer stated furnace was not operating at all found 120 V coming to board but no LED or low-voltage found bad transformer presented options HD3 a through E customer chose option C performed repair of transformer voltage absorption system flame sensing system and surge protection. Found voltage being stolen as well as an extra short trace back to voltage distribution system of AC system. Presented options HD2 a through E customer chose option C performed voltage distribution system repair as well as cleaned condenser coil and replaced voltage absorption system. Cycled system system currently running with 21° delta T. No further issues at this time


Jamie S.

Jamie S. Job Checkin

Cost to install air conditioner. Install price for ac

Cost to install air conditioner. Install price for ac

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 Bryant AC system found 45/5 voltage absorption system reading 43.7/5. 70.2 in Rush amps 88–108 hard start reading 105. Replaced customer supplied 213 filter. 70 RA 49 SA 21 degree deltat. No issues found at this time.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2022 Bryan AC system. Found 45/5 voltage absorption system reading 43.7/4.8. 113 inrush amps. 65/44 21 degree deltat. No issues at this time. Customer will talk with husband about adding surge protection.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2012 Bryant AC system found45/5 voltage absorption system reading 45/5. 189-227 hardstart reading 199. 79 inrush amps nno issues found at this time.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2012 Bryant ac system. 45/5 Voltage resorption system reading 44.3/5-84 inrush amps. Left new 16251. Added tabs to drain


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2018 comfort maker AC system. Found 35/5 voltage absorption system reading 34.5/4.8. 81 inrush amps. Cleaned condenser replaced 16251 filter no issues found at this time.


Robby D.

Robby D. Job Checkin

Left quote for new 114/126 3ton system. Customer on schedule for next Friday 8am. Customer to go with 126 paying in cash


Jamie S.

Jamie S. Job Checkin

Cost to install central air conditioning and furnace.

Cost to install central air conditioning and furnace.

Robby D.

Robby D. Job Checkin

Responded to no heat. Gas company stated pressure loss past shut off. Checked for leaks via electronic gas leak detector. Found no sign of leak. Double checked for leaks with big blu micro leak micro bubble soap solution. Found no sign of leak around all joints and fittings. Customer was present to find no bubbles as well. Customer stated gas tech said it may be in gas control. Advised typical process is to shut off all gas shut offs and test to shut offs then once passing test use electronic leak detector on equipment side of line. Advised if he allowed any psi to gas valve gas valve would not be able to hold pressure back. Cannot confirm or deny. No obvious sign of gas leak at gas valve. Offered to replaced gas valve Customer is not interested at this time. Advised customer of service club as well as furnace age. 02 furnace. Started furnace up. Found 0 ppm co in flu. Furnace operating properly at this time. No gas leak found near shut off via bubbles or electronic detector. Colle


Robby D.

Robby D. Job Checkin

Upon arrival thermostat stated pressure switch closed inducer off. Found pressure switch stuck closed not allowing furnace to cycle. Opened pressure switch circuits. Cycled multiple times. Furnace running at this time. Found 12” return quoted 1z4 b-E with pressure switch repair included. Customer chose option b. Will return tomorrow with parts to repair


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 10 rheem furnace. Found concern with 15 voltage absorption system reading 11. Found furnace running with 7%o2. 8 ppm co in flu. 33 degree delta t. Presented hn10a-e. Customer will hold off for now. Cleaned flame sensor. Spark ignition.


Joel  T.

Joel T. Job Checkin

Heat pump maintenance inspection all systems operating at this time.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 10 rheem furnace. System running with 7.8% o2 8 ppm co in flu. 0 ppm co in supply no concerns at this point 41 degree delta t. 10 voltage absorption system reading 10 left new 16251 filter