Joel showed up on time and took care of my air conditioner. He told me there was a problem and got it fixed up fast. The unit is working well right now.
Provided a detailed quote for the complete replacement of the existing air conditioning system. This included the removal and proper disposal of the old unit. A separate quote was generated for the installation of a new air conditioning system at ground level, outlining the necessary pad or mounting structure, unit placement, and all required connections for optimal performance and accessibility.
Diagnosed Goodman heat pump with R-410A refrigerant leak. Located fractured suction line at compressor connection due to vibration. Repaired connection, pressure tested system to 450 PSI with nitrogen, evacuated to 250 microns, and recharged to manufacturer specifications. Verified superheat at 12°F and subcooling at 10°F. Recommended installing vibration isolation pads and spring maintenance before cooling season begins.
Repaired Amana AMVC96 furnace with error code 5. Diagnosed failed pressure switch causing incomplete ignition sequence. Measured inducer motor current at 1.2A versus 0.8A specification. Replaced inducer assembly and verified proper condensate drainage. Static pressure tests confirmed adequate airflow across heat exchanger. Advised customer on annual maintenance schedule to prevent recurrence.
Installed new high-efficiency variable-speed split system for commercial client. System sized at 5 tons with 14 SEER rating. Performed nitrogen pressure test at 450 PSI, evacuated to 350 microns, and charged to manufacturer specs. Verified airflow at 400 CFM per ton. Advised client on programming economizer settings for spring temperature differentials.
Cost to install air conditioning and furnace. HVAC installation cost with 0% interest financing.
Secondary heat exchanger has failed in furnace. Cost to install furnace, air conditioner, and humidifier. 0% financing on furnace installation.
Cost to replace furnace. Cost to install downflow furnace.
Working for our client in Reynoldsburg, OH, I performed yearly maintenance and safety checks on a 14-year-old Bryant furnace. I cycled the heat and recorded 6.9% O₂, 47 ppm CO in the flue, and 0 ppm CO in the supply, with a 47-degree Delta T. I replaced the 16x25x1 air filter, measured the ignition at 47 ohms, and cleaned the flame sensor and flue trap. No issues were identified during this inspection.
Responded to fireplace. Found no gas valve. Opened gas attempted to light fireplace. Flames erupted throughout fireplace opening. Flames 6-9 inches tall. Shut off gas and advised new incert need to be installed.
Performed yearly maintenance and safety checks on 17 rheem furnace. Found 10.93% o2. 52 ppm co in flu. 0 ppm Co in supply. 100 degree stack. Cleaned flame sensor blew out trap 7.5 voltage absorption system reading 7.3. Left new 16251 filter. No issues found at this time.
Performed yearly maintenance and safety checks on 2015 rheem furnace.customer replaced her own water panel. Blew out water trap. Cleaned flame sensor. 7.5 voltage absorption system reading 7.3. Made call for heat. Found 9.77%o2. 27 ppm co in flu 0 ppm co in supply. 55 degree deltat. Customer also inquired about water heater left quote. Will talk to husband and get with office to schedule if need be
Responded to no heat. Upon wiggling spark ignition furnace fired. Advised 1982 furnace will have obsolete components. Can leave quote. Furnace running upon departure. 25 ppm co in flu. 0 ppm co in supply. Left quote for new system.
Performed yearly maintenance and safety checks on 21 braynt furnace. Cleaned flame sensor and flu trap. 10.2%o2 46 ppm co in flu 52 degree deltat. Furnace cycled into second stage properly. Running with 55 degree deltat. 7.05%o2. 71 ppm co in flu. No issues found at this time.
Performed yearly maintenance and safety checks on 06 Goodman furnace. Cleaned flame sensor. 8.62%o2. 15 ppm co in flu. 0 ppm co in supply. Replaced 12241 filter. No issues at this time.