3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for upper arlington, oh

Rated 5.0 out of 5 stars based on 2 customer reviews

Great Service!!

We recently moved back into the area and when it comes to anything related to HVAC our choice was simple! Sears Heating and Cooling! Professional, thorough, and made appropriate recommendations given the age of our furnace. Simple transaction and confident going into the Winter.


Response from Sears Heating & Cooling:

Thank you for the 5 star rating. We sincerely appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Josh was great! Super knowledgeable and friendly. Will be using Sears again in the future for sure

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for upper arlington, oh

Josh S.

Josh S. Job Checkin

Two ac check on Goodman Bryant filters 16-25-4. 20-25-4

Two ac check on Goodman Bryant filters 16-25-4. 20-25-4

Josh S.

Josh S. Job Checkin

Ac check Bryant 20-25-5

Ac check Bryant 20-25-5

Josh S.

Josh S. Job Checkin

I conducted a repair on a 2004 Comfortmaker HVAC system operating with R22 refrigerant. The service included replacing a worn compressor capacitor and recharging the system with R22 to restore optimal cooling efficiency. I also checked and secured all electrical connections to ensure reliable operation moving forward.

I conducted a repair on a 2004 Comfortmaker HVAC system operating with R22 refrigerant. The service included replacing a worn compressor capacitor and recharging the system with R22 to restore optimal cooling efficiency. I also checked and secured all electrical connections to ensure reliable operation moving forward.

Jamie S.

Jamie S. Job Checkin

Cost to replace central air conditioning. Price to install new air condition.

Cost to replace central air conditioning. Price to install new air condition.

Josh S.

Josh S. Job Checkin

Changed 16251 filters. Pvc drain line looks good. 2021 AC r410. 60 degrees outside. Electrical was tightened. 40/5 @ 40/5. Amp draw was 66.7. Coil is clean getting a 20 degree split

Changed 16251 filters. Pvc drain line looks good. 2021 AC r410. 60 degrees outside. Electrical was tightened. 40/5 @ 40/5. Amp draw was 66.7. 
Coil is clean getting a 20 degree split

Josh S.

Josh S. Job Checkin

Perform maintenance and safety check on 1995 Brian Bryant system filter 16 x 25x1 capacitor 35/5


Robby D.

Robby D. Job Checkin

Performed yearly maintenance of cc checks on 2006 Bryant AC system. Cleaned condenser. 50/7.5 reading 48/7.5. 61 inrush amps. Replaced customer supplied filter. No issues found at this time.


Jamie S.

Jamie S. Job Checkin

Cost to install central air conditioning and furnace

Cost to install central air conditioning and furnace

Wally T.

Wally T. Job Checkin

Annual maintenance check on a carrier heat pump


Ramon R.

Ramon R. Job Checkin

Addressed a failed inducer motor in a Luxaire furnace, promptly replacing the malfunctioning component. Conducted thorough testing to guarantee proper ventilation and safety.


Ramon R.

Ramon R. Job Checkin

Successfully replaced a malfunctioning inducer motor in a Luxaire furnace, ensuring proper ventilation and combustion. Conducted additional checks to guarantee the overall efficiency of the heating system.


Ramon R.

Ramon R. Job Checkin

Replaced failed inducer motor and faulty collector box on comfortmaker furnace.


Ramon R.

Ramon R. Job Checkin

Performed furnace, maintenance and safety checks on comfort maker and temp star units.


Ramon R.

Ramon R. Job Checkin

Performed annual furnace maintenance and safety check on a Bryant unit. The furnace is running smoothly and heating rooms evenly.


Josh S.

Josh S. Job Checkin

2022 90% comfortmaker 2 stage 90%. Installed by butler. Good install Filters 20-25-4+2 We spoke about humidification benefits He will consider Electrical secure Flame sesnor clean Trap clean Co in flue is 10/8 Eco bee stat Added tab to drain

2022 90% comfortmaker 2 stage 90%. Installed by butler. Good install 
Filters 20-25-4+2
We spoke about humidification benefits He will consider 
Electrical secure 
Flame sesnor clean 
Trap clean 
Co in flue is 10/8
Eco bee stat 
Added tab to drain