4401 Eastern Ave #17
Baltimore, MD 21224
410 781-1002

Local Reviews
for baldwin, md

Rated 4.8 out of 5 stars based on 5 customer reviews

Yonas was very professional and courteous.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The gentlemen were friendly did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Yousef is wonderful!!

Yousef is an asset to supreme air. Very friendly and helpful. Supreme air is lucky to have him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Rate

I love Youseff. He is very polite helpful and seems to know his job. The only improvement would be to please turn out lights and close doors and garage doors behind your exit. Marsha Hall

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service !

Very knowledgable and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for baldwin, md

Ashley M.

Ashley M. Job Checkin

Nearby Now


Yonas M.

Yonas M. Job Checkin

Nearby Now


Megan C.

Megan C. Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


marcm@supremeservicetoday.com

marcm@supremeservicetoday.com Job Checkin

Replace bottom elements


marcm@supremeservicetoday.com

marcm@supremeservicetoday.com Job Checkin

Replace bottom element of water heater. Customer refused to pay evaluation fee and refused to sign estimate due to rheem telling customer it would be free. We didn’t install the unit so we’re not responsible for damage that was done to water heater. Customer is waiting for word from rheem weather or not the charge will be covered. Customer thought we were replacing the element for the evaluation fee.


Christopher  A.

Christopher A. Job Checkin

Customer recently replaced the air filters for each unit. I checked the electrical wiring and electrical systems, including the auxiliary heat strips and all are within specification. I operated the units on second stage heating mode and measured heat of extraction for each unit which is right at 50,000 btu/hr which is slightly better than printed data. I pressurized each ground loop to 65psi. Both units are operating normal. I gave the customer an estimate to install a humidifier on unit #2, which serves the downstairs area. I also noticed that neither electrical panel has any form of surge protection and highly recommended adding whole house surge protectors to each of the 2 main electrical panels.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections inspected water pressure,coil,cap,Contactor,filter,unit operating normal


ALEX K.

ALEX K. Job Checkin

Duct cleaning whole house


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Fall pm 10/17/19 on arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced units operating normal at this time.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

When I arrived I checked furnace and filter and sure it as in correctly with arrow showing towards unit. This furnace has two places to install filter all ok. Customer sign up for membership for one year and would like for us to come back out 10/03/19 & 12/3/19


Youssef  D.

Youssef D. Job Checkin

Up on arrival found system low on charge, put one pound of 410A , unit operating normal at this time. Customer declined leak check and repair. We recommended to replace system.


Yonas M.

Yonas M. Job Checkin

Service call on 08/13/19 On arrival set units to call for cooling checked condenser unit outdoor found error codes on comfort alert #1 long running compressor checked electrical connections checked voltage and amps checked compressor capacitor checked coil reset the unit from mean breaker tested checked amps for compressor checked pressure and temp and they are ideal indicating zero leaks measured subcooling and superheat measured supply and return air temp stayed for 30 minutes unit operating normal at this time. Collected $105.40 for diagnostic fee and $50.15 for dispatch fee total $155.55 On C.C


Christopher A.

Christopher A. Job Checkin

I replaced both loop pumps on the unit that serves the upstairs. Both pumps were locked up. Tested the unit for normal operation. I replaced the EZ trap on the main level unit. It was leaking at a joint that could not be glued again. Unit operating normal. I let the customer know that I was finished and that they could turn the unit back on to cooling.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Replaced blower motor that was constantly shutting system off with error 41 with new motor. Tested system by cycling at thermostat and took amp readings on motor. New motor functioning properly.