4401 Eastern Ave #17
Baltimore, MD 21224
410 781-1002

Local Reviews
for davidsonville, md

Rated 5.0 out of 5 stars based on 3 customer reviews

Very knowledgeable service technician

Double checked all parts to be repaired. Made necessary repairs quickly and efficiently. Very trustworthy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service as usual

Tech was courteous and professional. He explained what he was going to do and why.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding service


Response from Supreme Service Today:

Thank you so much for the outstanding review! We're so glad to have provided such outstanding service during our visit. We're hoping to continue this in the future for all of your HVAC & Plumbing needs. Have a supreme day!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for davidsonville, md

youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


Colin T.

Colin T. Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com Job Checkin

Nearby Now


Megan C.

Megan C. Job Checkin

Nearby Now


Christopher  A.

Christopher A. Job Checkin

Nearby Now


Christopher  A.

Christopher A. Job Checkin

Nearby Now


Christopher  A.

Christopher A. Job Checkin

Nearby Now


Christopher  A.

Christopher A. Job Checkin

Fix water leak on copper tubing for radiator. What would have been a much quicker repair took longer because the section of radiator would not drain. I found a short piece of 3/4 copper and 2 couplings and cut into the leaking pipe to force it to drain. Once the water was out of the pipe, the repair was achieved. I turned the water back on and the boiler. Radiators are heating and there are no leaks. It’s an oil burning boiler but customer had no issues with it and was aware that I could not service it.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Service call on 11/29/19 On arrival customer explained to me one of her unit thermostat it was red set needs service I set the unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter checked EWP and LWP also water temp measured pressure and temp and unit indicating zero leaks unit operating normal at this time. No repair collected $124 diagnostic fee on C.C on file.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Up on arrival found system was flat on charge. Found King and king valve was not open all the way . Opened valves all the way , charged system with nitrogen at 400psi, hold it for 45 minutes all pressures stayed still. Released nitrogen, pulled vacuum on system. Changed system with R410A , ran out our refrigerant, got as close as I can get to preferred pressures, took delta T is 26, need return visit sometime in couple weeks to check up on the system. Unit working at this time.


Yonas M.

Yonas M. Job Checkin

Fall pm on 10/24/ 19 On arrival I sanded the flame rectification probe and checked burner arrangement the ignitor homes out to be in good condition checked all other electrical connections set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked blower motor checked all other electrical connections checked temp rise DT 47 made for 35-65 checked condenser unit checked pressure and temp and they are ideal indicating zero leaks checked compressor capacitor checked coil unit tested unit operating normal at this time. Recommended Uv lights installation and DUCT Cleaning also Wet switch for unit #2.