Scott S.

Scott S. Job Checkin

I performed the seasonal maintenance per agreement. The downstairs is 11 years old. I recommended replacing the system due to cost of future repairs,age condition and r22 phase out. They are planning on replacing it soon


Scott S.

Scott S. Job Checkin

David called and had her reset the reminder


Scott S.

Scott S. Job Checkin

Changed filters, checked thermostats, checked heating elements and blower amps, checked evap coils, checked drain pan & blew out drain line, checked/tightened electrical connections, checked capacitor (compressor side 35uF and it has 32.5uF), checked fan and compressor amps, checked pressures and reversing valve, cleaned condenser coils. Entered Trane air handler manufacturing info. Customer renewed membership last week. 1 system: 2012


Scott S.

Scott S. Job Checkin

Warranty call. Per Ruud factory rep. I replaced the high pressure switch, installed a new defrost circuit board and changed the filter drier. Pressure tested braze joints with nitrogen. Pulled a vacuum and weighed in factory charge of r410a refrigerant, then charged system to proper subcooling. Injected ac renew into refrigerant system. The unit made the noise once and hasn’t made it again. System and defrost operation is significantly quieter. Told client the system will need 24-48 hours for the ac renew to properly circulate throughout the entire refrigerant system.


Scott S.

Scott S. Job Checkin

Checked filters (Customer is changing), checked thermostats, checked elements and blowers amps, checked evap coils, checked drain pan and blew out drain lines, checked/tightened electrical connections, checked blower capacitor, checked capacitors, checked fan and compressor amps, checked pressures and reversing valve (2015 unit was a little low), and checked condenser coils (No outside water). 2 systems: 2015 & 2013


Scott S.

Scott S. Job Checkin

I performed a one time clean and check. All amps,volts,capacitors and pressures are withen specs.


Scott S.

Scott S. Job Checkin

Inspected wiring and devices damaged from flood. Worked up quote


Scott S.

Scott S. Job Checkin

Tripped GFI for landscape lighting transformer. Reset.


Scott S.

Scott S. Job Checkin

Checked filter, checked thermostat, checked elements and blower amps, checked evap coil, checked drain pan, blew out drain line, checked/tightened electrical connections, checked capacitor, checked fan and compressor amps, checked pressures and reversing valve, cleaned condenser oils. 1 system: 2017


Scott S.

Scott S. Job Checkin

Service agreement clean and check on a 6 year old split heat pump system. Cleaned evaporator coil. Flushed out drain line. Checked heat strips and blower motor operations. Washed and waxed outdoor unit. Romoved debris from the bottom of the condenser. Brushed out debris from electrical compartments. Checked refrigerant,mechanical and electrical operations. Ductwork is clean. Changed the main filter for the client they provided. The bonus room air filter is clean because the client don’t live here full time yet. Zone board and zone dampers are working correctly. Recommend a start booster for the heat pump outside to lower the cranking amps on the compressor.


Scott S.

Scott S. Job Checkin

i replaced a 12x12 square damper and checked the operation. Complete.


Scott S.

Scott S. Job Checkin

Checked filters, checked thermostat, checked elements and blower amps, checked evap coil, checked UV light, checked pan strip, checked drain pan, blew out drain line, checked capacitor, checked fan and compressor amps (compressor was a little high), checked pressures and reversing valve, cleaned condenser coils coils. 1 system: 2016


Scott S.

Scott S. Job Checkin

Checked filters, checked thermostats, checked elements and blower, checked evap coil, checked drain pan and line, checked capacitor, checked fan and compressor amps, checked pressures and reversing valve, cleaned condenser coils. 1 system: 2015


Scott S.

Scott S. Job Checkin

The system was working on arrival. Homeowner stated he did cut the power to try to reset the system.


Scott S.

Scott S. Job Checkin

Performed routine maintenance performed routine maintenance room 2012 bosch system Checked indoor blower motor checked contactor checked capacitor checked compressor checked pressure cleaned the coil checked the temperature unit is working OK at this time