Scott S.

Scott S. Job Checkin

Replaced all smoke detectors and co2 detectors throughout home.


Scott S.

Scott S. Job Checkin

Replaced all smoke detectors and combination detectors throughout home.


Scott S.

Scott S. Job Checkin

Quote for changing out of smoke detectors


Scott S.

Scott S. Job Checkin

Quote for changing out all smoke detectors


Scott S.

Scott S. Job Checkin

Service agreement clean and check on an 8 year old split heat pump system. Washed and waxed outdoor unit. Flushed out drain line. Cleaned evaporator coil. Brushed out debris from electrical compartments. Tightened all electrical connections. Checked all electrical and mechanical operations. Checked zone system. Installed a new start booster on the outdoor unit. System refrigerant charge is good. Ductwork is clean.


Scott S.

Scott S. Job Checkin

Service agreement clean and check on a split heat pump system. Cleaned evaporator coil and drain line. Washed and waxed outdoor unit. Brushed out debris from electrical compartments. Tightened all electrical connections. Checked all electrical and mechanical operations. Evaporator coil in air handler is in good condition, it was changed recently. Compressor and condenser fan motors both at 60 megaohms. Outdoor unit is showing signs of age and Ware. Recommend have the ductwork cleaned and sanitized and upgrade the system to a more efficient unit that’s reliable.


Scott S.

Scott S. Job Checkin

Changed filter, checked thermostat, checked elements and blower, checked evap coil, checked the drain pan, sucked out drain line, checked/tightened electrical connections, checked capacitor, checked fan and compressor amps, checked pressures and reversing valve, cleaned condenser coils. 1 system: 2017


Scott S.

Scott S. Job Checkin

Service agreement clean and check on a 3 year old split heat pump system. Washed and waxed outdoor unit. Flushed out drain line. Cleaned evaporator coil. Tightened all electrical connections. Brushed out debris from electrical compartments. Cleaned out leaves from bottom of condenser. Checked all electrical and mechanical operations.


Scott S.

Scott S. Job Checkin

Cleaned vents, sanitized return, installed UV light, could not collect nobody was home


Scott S.

Scott S. Job Checkin

Service agreement clean and check on a 9 -10 year old split heat pump system. Went to clean the evaporator coil. Noticed residual oil on the evaporator rings and bottom of drain pan. Checked refrigerant level. System has a leak on the evaporator coil , checked charge and it it approximately a little less than half low. Checked over rest of system. Low pressure switch has been bypassed at some point in the past, that’s why the system kept running out side. Client wanted prices on a new coil vs. prices on replacing the system. Client is going to change the system but needs to wait till Saturday when his wife gets home to see if they want to go ahead and pay for it or finance it for 12 months.


Scott S.

Scott S. Job Checkin

Prepaid Preventative Maintenance: Verified Refrigerant pressures in cooling mode, heating strips operation, cleaned condenser coils/drains, tightened electrical connections & verified amp draw is good, capacitors charged. Installed UV light for Duct Cleaner. Units are in excellent condition & running very efficiently! INSTALLED 2016


Scott S.

Scott S. Job Checkin

Prepaid Preventative Maintenance: Verified System Pressures, Heating strips operation, tightened electrical connections & verified amp draw at compressor. Cleaned condenser coils/drains, adjusted fresh air intake & checked capacitors. No problems found, both systems in very good condition running very efficiently!


Scott S.

Scott S. Job Checkin

Diagnostic call. Renters said outdoor unit is making a noise. Turned system on. System came on then blower stopped running. Looked over air handler in the attic and unit outside. Clients thermostat is bad. Explained that the outdoor unit will be very loud if the blower isn’t running. Put pictures in equipment of old thermostat. Installed a new thermostat. Ran system. Unit is heating and cooling properly now.


Scott S.

Scott S. Job Checkin

Two service agreement clean and checks on 3 year old and 10 year old split heat pump systems. Washed and waxed outdoor units. Cleaned evaporator coils. Tightened all electrical connections. Brushed out debris from electrical compartments. Flushed out drain lines. Installed a Stay clean strip in the main system drain pan. Ductwork is clean on both units. Newer system checks out well. Older bonus room system has rusty expansion valves and the condenser coil is getting corrosion.


Scott S.

Scott S. Job Checkin

I replaced the thermistors and unitary control under warranty. Complete