Scott S.

Scott S. Job Checkin

Replaced warranty service Protector


Scott S.

Scott S. Job Checkin

Quote for solar attic fan.


Scott S.

Scott S. Job Checkin

Gave quote for outdoor panel change.


Scott S.

Scott S. Job Checkin


Scott S.

Scott S. Job Checkin

Performed routine maintenance on three-year-old package system checked heat strips checked blower motor checked condenser motor checked capacitor checked contactor checked compressor cleaned coils checked pressure checked temperature unit is working ok at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on 2012 Goodman system checked heat strips checked blower motor checked condenser motor checked capacitor capacitor was weak and replaced checked compressor checked contactor cleaned both coils checked pressure checked temperature unit is working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance checked heat strips checked blower motor checked condenser motor checked compressor checked capacitor checked contactor checked temperature checked pressure cleaned both coils unit is working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two 2015 ruud systems checked heat strips checked blower motor checked condenser motor checked compressor checked contactor checked capacitor checked temperature checked pressure cleaned both coils cleaned the drains units are working OK at this time


Scott S.

Scott S. Job Checkin

Replaced 6 bay lights.


Scott S.

Scott S. Job Checkin

Perfomed routine maintenance on On two systems 2016 and 2017 checked heat strips checked blower motor checked condenser motor checked capacitor checked contactor checked compressor checked pressure checked temperature cleaned both coils units are working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on 2011 double system checked heat strips checked blower motor checked condenser motor checked compressor checked capacitor checked contactor checked the pressure checked temperature units working OK at this time replaced uv bulb and customer had 20 coupon


Scott S.

Scott S. Job Checkin

Performed routine maintenance on a five-year-old Lennox system checked heat strips checked blower motor checked condenser motor checked capacitor checked compressor checked contactor checked pressure checked temperature checked drain cleaned both coils unit is working OK at this time


Scott S.

Scott S. Job Checkin

I checked both systems. The up bulbs will be due for replacement next service. I recommended sta clean strips. Homeowner stated he was very upset with the company and wasn’t using us anymore. See concern form.


Scott S.

Scott S. Job Checkin

I checked the system and all components in cooling. The system is locked out on low pressure and completely out of refrigerant. I looked the system over for obvious signs of leaks. We need to schedule a leak search due to the weather. There is also heavy of growth in the airhandler,I highly recommend a uv light,duct cleaning and fogging to eliminate this and prevent it from reoccurring. Get code for entry from Sloan realty and perform a leak search.


Scott S.

Scott S. Job Checkin

Quoted panel