Replaced 30 amp breaker with a 35amp breaker for A/C. Wired up a/c. Wired up the air handler. Air handler called for 60 amp breaker. Breaker was correct size.


Scott S.

Scott S. Job Checkin

Install new generac gen


Scott S.

Scott S. Job Checkin

Whole house inspection. Two bathroom GFI receptacles need to be replaced. 3 Eaton 15 amp arc fault breaker’s need to be replace. Motion sensor lights to be replaced. All receptacles in house are fine.


Scott S.

Scott S. Job Checkin

Replace two landscaping lights


Scott S.

Scott S. Job Checkin

Checked range receptacle and breaker for possible burning of wire. Range receptacle was fine and breaker as well.


Scott S.

Scott S. Job Checkin

Added 1/40 amp breaker for heat 1/40 amp breaker for heat pump


Scott S.

Scott S. Job Checkin

Replaced floor outlet cover.


Scott S.

Scott S. Job Checkin

Found short in the outside lights


Scott S.

Scott S. Job Checkin

Helped John Evans


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two systems checked heat strips checked blower motor checked condenser motor checked capacitor checked contactor checked compressor cleaned both coils checked temperature checked pressure checked drain units are working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on two systems 2013 checked heat strips checked blower motor checked condenser motor checked capacitor checked contactor checked compressor cleaned both coils checked temperature checked pressure units working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on 2011 ruud system and 2015 Goodman system checked heat strips checked blower motor checked condenser motor checked compressor checked capacitor checked contactor checked temperature checked pressure checked drains cleaned both coils units are working OK at this time


Scott S.

Scott S. Job Checkin

Performed routine maintenance on 2012 Goodman system checked heat strips checked blower motor checked condenser motor checked capacitor checked compressor checked contactor checked temperature checked pressure cleaned both coils unit is working OK at this time


Scott S.

Scott S. Job Checkin

To replace the coil sensor under warranty. Order sensor. Systems 5 years old


Scott S.

Scott S. Job Checkin

I performed the seasonal maintenance per agreement. The uv bulb will be due for replacement next service to maintain effectiveness. Recommend a sta clean strip to help prevent clogged drains. System is working properly in cooling.