Response from Swift Services Heating & Cooling:
Thank you for sharing your recent HVAC service with us, we are glad to hear you received Excellent service.
Changed out arc fault breaker
Preformed first prepaid maintenance services on a Goodman split heat pump unit, model and serial numbers match in the system. Replaced the filter and checked pressures checked amp draws and checked wiring connections. Cleaned coils and cleaned drain line, added algecide treatment to drain pan for drain line prevention. Tested float switch and tested temperature split. Delta-t is 22 degrees and heat pump heat supply is 106 and climbing. Heat strips engage and disengage with a 2 degree temperature call over what it is inside. Heat strips are working properly. After completion of maintenance all systematic components are working properly at this time.
Service call- front bedroom is not cooling properly. Found a kink in the duct work and duct work not sealed to ceiling. Straightened duct and sealed and insulated duct where register is connected from attic to room. Air flow is better. Air now only supplies that bedroom with air instead of the attic as well.
Preformed prepaid maintenance on a Goodman split heat pump unit, model and serial number match in the system. Checked the filter and checked pressures, unit pressures are correct for the temperature outside. Checked amp draws and checked wiring connections. Cleaned coils and cleaned drain line. Added mildew destroyer to drain line to help prevent bacteria build up. Checked the temperature split and got 21 degrees. Tested float switch. All systematic components are working properly at this time.
Preformed prepaid maintenance on a Goodman Amana split heat pump system, model and serial number match in the system. Replaced filters and checked pressures checked amp draws and checked wiring connections. Cleaned coils and cleaned drain line. Added algecide treatment to drain pan for drain line prevention. Tested float switches. Inspected duct system and it has a lot of pollen and dust. Quoted 590.00 for a duct cleaning. 11 supply vents and 2 returns. Tested Air flow and split and got a 23 degree split. He’s also interested in a blue tube uv kit. Quoted 370 for kit. All systematic components are working properly at this time.