Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
Jason found the problems and got air working. I do hope that he returns for the follow up repair. Thank you again.
Good tech-knowledgeable
Response from Swift Services Heating & Cooling:
Thank you, Sammy, we like to provide our customers with excellent service through hard work, explaining procedures, so the client understands the work being done, and keeping a clean workspace!
Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
Great job again! Very detailed analysis of my situation.
Response from Swift Services Heating & Cooling:
Thank you, Charles, our technicians like to work diligently and check all ends before jumping to conclusions to make sure we get to the bottom of the issue, so you can enjoy the air conditioning.
Good job. Courteous, explain things well. Well satisfied with Experience
Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
First time with this company. Great service!
Response from Swift Services Heating & Cooling:
Thank You, please refer us to your Neighbors, friends, and family
Response from Swift Services Heating & Cooling:
Thank you, Tracey, for your 5-star rating.
Response from Swift Services Heating & Cooling:
Hi Paul, we know how stressful it can be to not have AC when it starts to get hot, which is why we do our best to diagnose the problem as swiftly as possible so we can make your home comfortable again!
Cleaned and serviced Goodman split heat pump. Pressures checked good. Heat strips checked good. Capacitor checked good. UV light checked good. Cleaned evaporator coil and condenser coil. Cleared drain pan and vacuumed drain line. Unit is functioning properly upon completion.
Cleaned and serviced Goodman split heat pump. Pressures checked good. Heat strips checked good. Capacitors checked good. Cleaned evaporator coil and condenser coil. Cleared drain pan and vacuumed drain line. Unit is functioning properly upon completion. Attic access has to be pushed towards tv, the drywall there now is broke in half won’t last much longer.
Cleaned and serviced Lennox package heat pump. Pressures checked good. Heat strips checked good. Capacitor checked good. UV light was burnt out, replaced and moved to correct side of coil. Cleaned evaporator coil and condenser coil. Cleared drain pan and drain line. Cleaned up thermostat wiring. Added deoxide to service disconnect. Unit is functioning properly upon completion. Office to collect.
Installed doorbell and replaced two bathroom fixtures
Quote to repair doorbell and replace bathroom light fixtures
Replaced coil. Pressure test 500 psi Pull vac to 450 micron Charged system with 7 lbs 410A
Found large oil residue in Evap coil first sign of a large leak System pressures. Customer agreed to coil replacement . Waved. Service fee for military discount. Need to replace coil and schedule maintenance.
Found system slightly low on r22 Found contractor pitted and defrost control not working properly Client would like comfort advisor to come out and quote for an upgrade.
Super tuneup. Checked heat strips and reversing valve. Checked pressure of the unit as well as capacitor. Cleaned off the unit itself and it’s coils. Unit is functioning properly upon completion and was well handled. Customer was very kind hearted and offered me some hot cocoa while I was out in the cold.
Indoor unit Blower amps are in range Run cap is borderline weak and should be replaced to prevent failure Reading 9.6 and the minimum is 9.5. / 10 Cabinet contains biological growth and should be addressed with preventative measures. The air handler is trapped outside and does not have a primary safety switch . This could cause flooding in the event of a drain line back up Outdoor unit Coils are clean, amps are in range Pressures are in range Run cap is below weak and should be changed today. Reading 25/4.9 supposed to be 45/5 Replaced the run cap under warranty Once the system has started and is operating, the run capacitor takes over and provides the extra power to run the air conditioner for long periods of time. When the air conditioner is running, both capacitors create and store energy for the push for the next cycle.
Condenser coils and Evap coils need cleaned Cats have gotten under home by the back porch and chewed holes in the ductwork . Need 12†flex installed. Mail hard copy of receipt for service fee and ductwork repair.
Completed tune up and educated and informed on renewing customer want to wait