Performed a heating maintenance on two furnaces. Older systems but running within specifications. Service bonsall
Performed the heating maintenance on three systems. Replace the capacitor for the system that heats the dining room.
Hydro Jett line and trace out the drain line. Jay was with me and I showed him direction and depth. Root intrusion area and a rock that is in the pipe. He’s going to reroute the line to accommodate a pool. There is a belly in line that he will cut before it to offset the line to go around the pool.
Customer ran out of propane. Customer called propane company to fill tank. Thompson plumbing reset furnace. Ran thermostat to test unit. Furnace works fine for now.
Current unit is a rannai that is leaking and stopped working. We will install a new noritz unit in the recessed metal box. Install of new service ports. The current set up for wiring is hard wired to the fuse panel. The T&P will be stubbed on the side of metal box to out side. The vent exhaust discharge area might be adjusted to new setup on the front metal panel. This will be a LP gas tankless unit. Installed new unit and made a metal extension for the venting. New unit was further back then previous one. Tested and adjusted temp to max 140 as per client request.
Customer installed bathroom faucet and the cold side handle is crooked. The sink was clogged but customer used drain all. Also needs estimate for gas leak investigation for family room fireplace. Gas is off to fire place only. Thompson plumbing readjusted cold side handle. Ran water to test for leaks. No leaks found. Water drains fine for now. Cleaned up work area. Collected payment.
Performed the annual heating maintenance. System is performing within mfg specs. Replaced the air filter.
Performed a heating and cooling maintenance on all four systems. Customer declined maintenance of the Firth system which is a mini split.
Replace Kohler shower cartridge in master bathroom . Found small rocks stuck inside the cartridge which is why the shower no longer was spraying water .
Upon inspection under kitchen sink no leak was seen when running water thru drains and running dish washer. Client will keep a eye on it and let us know if it happens again.
Removed old water filter from water main line.
Upon arrival leak had stopped under kitchen sink. No work performed.
Two system cooling maintenance. Older systems but still functioning within mfg specs. Replaced a dual cap, sealed lineset penetrations and reinsulated the line set. Service in bonsall.
Cooling maintenance. Evaluation of system showed no issues and that the system is running well within mfg specs. Service bonsall.