DISPATCH - ca scheduled for tomorrow 5/17/24 @ 5 pm. I already spoke w/Service Call/ Maintenance Performed Today- Filter sizes- 19x20x4 Filter Condition- fair Unit age- 2013 Unit condition- poor, refrigerant leak Thermostat- carrier On arrival found the following- All tsat are off Indoor Unit- attic Blower amps- 1.5 Blower Capacitor- na Blower Type- variable Heat amps- 19 Drain- clear Float Switches- good Cleanliness- yes Outdoor Unit- heat pump Compressor amps- 36 Outdoor fan amps- .4 Capacitors- within specs Pressures are- 170/300 Refrigerant type- 410a Superheat- 9.9 Sub-cooling- 4.3 Temperature difference- Temp in- 68 Temp Out- 79 Duct Condition- great Insulation in Attic- great Notes- CA scheduled 05/18/24 @ 5 pm