Rated 5.0 out of 5 stars based on 1 customer reviews

Polite and professional

Very patient and good with education


Response from Trenchless Innovations Inc.:

Thank you for your kind words, Russell! We appreciate you choosing Trenchless Innovations for your underground air duct inspection. We hope that Rob's information provided you with the tools you need to complete the repair. We are grateful to have you as a customer and we are here should you have any further questions regarding the work Rob performed. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bloomingdale, il

Kevin W.

Kevin W. Job Checkin

Underground ducting repair for a customer in Bloomingdale, IL. Utilized advanced leak detection techniques to pinpoint issues, then implemented precise repairs to restore optimal airflow and insulation. Customer happy and not hearing the odd noises when system kicks on.


John R.

John R. Job Checkin

Just finished repairing underground ducting in Bloomingdale, IL. Identified and fixed leaks using advanced detection methods. Ensured good airflow and insulation for the customer's HVAC system. Job done right the first time.


 .

. Job Checkin

Under slab ductwork video inspection. Thoroughly checked ducts under home and discovered multiple places either close to failure or already leaking. Provided quote for spin cast mortaring and spray lining to repair ductwork leaks.


Bob S.

Bob S. Job Checkin

Under slab duct video inspection service call.Televised ducts under slab floor. Ducts are concrete with metal fittings that are rusted. Suggest spin cast mortaring the metal then spray line concrete ducts with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

Cleaned all underground duct work and applied first application of duct armor to all underground duct work.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings. Suggest spray lining ducts to seal joints for possible radon.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections that are rusting. Suggest spin cast mortaring metal fittings then spray lining ducts with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely encapsulated and the air in the home will be environmentally safe for the customer to breathe.


Kevin W.

Kevin W. Job Checkin

We are using our sewer cleaning equipment to precision clean the sewer of a condo building with 4 ground level units the 4” cast iron under the building was heavily scaled up and causing frequent sewer back up precision cleaning leaves a nice clean smooth cast iron pipe.


Jim D.

Jim D. Job Checkin

Televised underground asbestos transite air ducts. The metal connections and elbows are heavily rusted and there is water throughout the line.


Kevin W.

Kevin W. Job Checkin

Encapsulated underground asbestos transite air ducts with our duct lining product. The air in the home is now environmentally safe to breathe.


Bob S.

Bob S. Job Checkin

Video inspection of underground air ducts. Ducts are concrete possibly Transite asbestos with metal connections that are rusting. Suggest spray lining ducts with Duct Armor to restore the metal and encapsulate the transite.


Bob S.

Bob S. Job Checkin

Video inspection of under slab air ducts. Duct are concrete with metal fittings that are rusting. Box under furnace is also rusting. Suggest spray lining ducts with Duct Armor Duct lining material.