Trenchless did a great job! I would definitely recommend their service when you don’t want to dig up and old pipe.
Response from Trenchless Innovations Inc.:
Thank you for sharing your experience with our team, Bill! We appreciate your business and are glad our team could solve your sewer problem without digging up your pipes! Thank you for choosing Trenchless Innovations. We hope you enjoy a sewer free of problems for years to come!
I was glad I used Trenchless Innovations over others in the area as they were the only ones who offered cement casting of the metal ducting in my slab to increase its structural integrity and it turned out great.
Response from Trenchless Innovations Inc.:
Thank you for your kind words, Chuck! We are happy we could solve your air duct problem for you and we hope you're enjoying the cleaner and healthier air our process allows you! Thank you for choosing Trenchless Innovations. We are grateful for your business!
Televised and located existing sewer lines from multiple locations throughout the building to identify condition of pipe. Estimate for Descaling Provided.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. There is a blockage in the tee where a plumbing repair was made blocking the airflow to the back of the house. Floor will need to be broken up and blockage removed.
Applied second application of duct armor to all underground ductwork and furnace box.
Applied first application of duct armor to all underground ductwork and furnace box and register vents.
Televised and cleaned all underground ductwork. Applied trenchless spincast mortar to all underground ductwork. Repaired and rebuilt furnace box and all register vents with mortar as well .
Televised sewer from two different clean outs and will provide a quote for cleaning and descaling.
Conducted duct inspection using RIDGID SeeSnake microReel camera system. Identified severe rust and deterioration in galvanized under-slab ducts. Recommended two-step restoration process: 1) Spin-cast mortaring using Quikrete Commercial Grade FastSet Repair Mortar to rebuild structural integrity. 2) Application of Duct Armor elastomeric duct lining material using Graco Ultra Max II 595 PC Pro sprayer. This comprehensive approach will restore duct function, prevent air leakage, and significantly extend system lifespan without costly slab demolition.
Inspected ducts under the slab floor using a camera, identifying severely rusted metal ducts. Recommended the application of spin cast mortaring to rehabilitate the duct surfaces. Followed this by spray lining the ducts with Duct Armor duct lining material to ensure a durable, corrosion-resistant seal. This process will restore the structural integrity of the ducts and enhance their longevity and performance.
I recently completed a job where I adjusted downspouts and added gutters and downspouts to the customer's garage to resolve a water issue. I have updated the proposal and will resend it to the customer.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. Work needs to be done on outside of house to control water issues. After that the ducts should be spray lined with Duct Armor duct lining material.
Televised ducts under slab floor. DuCT’s are concrete with metal fitting. Will provide a proposal for spray lining to encapsulate the concrete ducts.
Under slab ductwork video inspection service visit. Televised ducts under slab floor. Ducts are concrete transite ducts with metal fitting and connections that are rusted and need to be spin cast mortared. After that ducts should be spray lined with Duct Armor to encapsulate sewer contaminated ducts.
Under slab ductwork video inspection service call. Televised ducts under slab floor. Ducts are concrete with metal fittings that are very rusted. Suggest spin cast mortaring then spray lining ducts with Duct
Hydrojetting service call. Performed descaling service as well. 12-6-2023: descaled 20’ of 4” cast sewer from outside clean out, jetted line clear upstream and to city main, installed 5’ spot repair liner from 4” outside clean out about 20-25’ upstream over area just downstream of 45 elbow where heavy roots were growing into sewer pipe.