1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Local Reviews
for bolingbrook, il

Rated 5.0 out of 5 stars based on 2 customer reviews

Great Service!

Trenchless did a great job! I would definitely recommend their service when you don’t want to dig up and old pipe.


Response from Trenchless Innovations Inc.:

Thank you for sharing your experience with our team, Bill! We appreciate your business and are glad our team could solve your sewer problem without digging up your pipes! Thank you for choosing Trenchless Innovations. We hope you enjoy a sewer free of problems for years to come!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Solved problem

I was glad I used Trenchless Innovations over others in the area as they were the only ones who offered cement casting of the metal ducting in my slab to increase its structural integrity and it turned out great.


Response from Trenchless Innovations Inc.:

Thank you for your kind words, Chuck! We are happy we could solve your air duct problem for you and we hope you're enjoying the cleaner and healthier air our process allows you! Thank you for choosing Trenchless Innovations. We are grateful for your business!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bolingbrook, il

Bob S.

Bob S. Job Checkin

Televised sewer from floor drain, kitchen sink, laundry tub and outside clean out. Cast is scaled but there do not appear to be major breaks. There is and area near the main bathrooms that have roots growing into pipe. There does not appear to have any areas that would cause water or moisture to appear on the floor. Also televised several under slab ducts and they are all dry with no water and no water in the plenum. Suggest opening wall behind laundry tub to see if water is coming from that area above ground.


Bob S.

Bob S. Job Checkin

Televised sewer from outside clean out. Heavy roots in clay and between cast and clay. Provide proposal for lining clay between pvc and cast.


Bob S.

Bob S. Job Checkin

Air duct inspection visit. Televised ducts under slab floor. Ducts are concrete transite with asbestos. Recommended immediate air duct repair. Will provide a quote for spray lining to encapsulate the asbestos pipes.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized metal ducts and are extremely rusted. Suggest spin cast mortaring ducts to restore structure then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings. Water getting into system during heavy rains. Bottom of plenum is rusted out. Downspouts and grading need to be addressed the. The ducts should be spray lined with Duct Armor duct lining material.


Jim D.

Jim D. Job Checkin

Cleaned 4 inch cast under footing. Installed a 4 foot fiberglass patch covering cast.


Josh R.

Josh R. Job Checkin

Applied first application of our rubberized duct lining material to all rusted underground duct work.


Kevin W.

Kevin W. Job Checkin

We are precision cleaning a clay sewer downstream about 45’ to city main heavy roots in some areas, also descaling 4” cast about 25’ upstream heavy scale build up holding paper and water, hydro jetting all loose scale and doing a video inspection of the sewer before and after.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work, applying our trenchless cast mortar to all the bad/ rusted metal fittings, and applying our duct lining material to all the underground duct work.


Kevin W.

Kevin W. Job Checkin

We are doing a video inspection of the underground duct work in a slab home


Kevin W.

Kevin W. Job Checkin

We are doing a video inspection of the underground duct work in a slab home which is a transite concrete duct with metal fittings that are rusting away, we are suggesting to trenchless cast the bad metal and apply 2 applications of our duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fitting and connections. Tee connection in laundry room area is heavily rusted as is the plenum. Other metal fittings look good n good condition. Concrete pipe is solid except for the area by the front door where pea gravel is entering g due to Duct dropped at that area. Suggest spin casting tee and plenum then spray lining all ducts to encapsulate the concrete.


Kevin W.

Kevin W. Job Checkin

We are applying our second application of the rubberized duct lining product to all the underground duct work


Josh R.

Josh R. Job Checkin

We are encapsulating all of the deteriorated underground asbestos transite air ducts with our rubberized duct lining material. The air ducts will be completely sealed and the air in the home will be environmentally safe to breathe.