1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for burbank, il

Rated 5.0 out of 5 stars based on 1 customer reviews

The service was great. Everyone who came to my home was very nice

Kevin was very professional knowledgeable and friendly


Response from Trenchless Innovations Inc.:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for burbank, il

John R.

John R. Job Checkin

I completed a sewer lining project in Burbank, IL, where I used a Perma-Liner system to rehabilitate a cracked sewer pipe. After cleaning the pipe with a hydro-jetter, I inserted the liner and inflated it, allowing it to cure and harden. This process restored the sewer line's functionality, preventing future leaks and root intrusion.


Jim D.

Jim D. Job Checkin

In Burbank, IL, I installed a cured-in-place pipe (CIPP) liner to rehabilitate a damaged sewer line. The original pipe had significant cracks and root intrusion. I used a resin-saturated liner, which was inserted and cured in place, forming a new pipe within the old one. This method restored the integrity of the sewer line without the need for excavation.


Jim D.

Jim D. Job Checkin

Conducted airflow balancing for 3-story office building. Used TSI AccuBalance 8380 capture hood to measure supply and return airflows. Adjusted dampers and cleaned supply diffusers. Replaced clogged filters with MERV 13 pleated filters. Calibrated Honeywell Prestige IAQ thermostats. Achieved balanced airflow within 10% of design specifications.


Kevin W.

Kevin W. Job Checkin

Rehabilitated 100-foot section of 10-inch concrete sewer main. Initial inspection with CUES OZIII robotic camera revealed multiple cracks and infiltration. Cleaned pipe with Aquatech B-10 combination jet/vac truck. Installed Nu Flow structural liner with epoxy resin. Cured using ambient air. Post-lining inspection confirmed fully restored structural integrity and flow capacity.


Kevin W.

Kevin W. Job Checkin

Televised some underground duct work for a customer that was getting a lot of dust/dirt in the house coming up from the duct work. The metal duct work was heavily rusted out, some areas there was no pipe left at all! We were able to clean all the ducts, apply our spin cast mortar to restructure and even create a new pipe where the old pipe was completely rotted away. After creating a new solid pipe to work with we were able to seal the ducts with our duct armor product leaving a clean air flow.