Televised the sewer from the outside cleanout next to the driveway. Found roots and cracking in the downstream section. The upstream section, near the house and cleanout, showed shearing in the cast iron pipe. Identified areas needing repair to prevent further damage and ensure proper flow. Recommending targeted repairs to address these issues and restore the sewer line's integrity.
Installed 4 1/2 ft spot repair liner from inside clean out in bathroom just past the cross from the toilet and sink ending in the 4” PVC.
Applied first application of our duct lining material to all rusted underground duct working.
Installed perforated sump pump pit outside of the house. Cored through the foundation wall and installed perforated drain tile below the underground air ducts to capture the water. Ran sump discharge line away from the house.
We are lining a sewer from a basement floor clean out, our customer is getting heavy tree root growth at the 4” cast to 6” clay pipe transition, lining through the area won’t allow tree roots to grow into the connection and cause frequent unexpected sewer back ups like before.
We are lining a sewer from an outside clean out out to the city main and also lining back towards the house into the 4” cast
We are applying the second application of our rubberized Duct Armor material to all of the heavily rusted underground duct work. The air ducts will be completely sealed and sand and dust will no longer enter the system.
We are applying our first application of our duct lining product to all the underground duct work, we have already cleaned the system and applied our trenchless cast to all underground duct work where needed.
The house we are working on has underground asbestos transite air ducts with galvanized metal connections and elbows. The connections and elbows are heavily rusted and sand and debris are blowing throughout the customer’s home. We are going to clean all of the sand and debris out of the air ducts. Next, we are going to apply our Trenchless Cast mortar to all of the heavily rusted connections to give them a strong structure. Lastly, we are going to seal the air ducts with our Duct Armor product.