Bob was extremely helpful and knowledgeable. I will definitely call Trenchless Innovations for any sewer services I need. They are always very responsive and professional.
Straight shooters
Response from Trenchless Innovations Inc.:
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
3-20-2025: cleaned and measured sewer in preparation for lining from 4” floor clean out in garage starting liner in 6” clay elbow just below 4” cast where bathroom ties in on riser for clean out and ending liner in 6” pvc before tee/wye from main run out of house. 4-15-2025: lined sewer from floor clean out in garage 39’ downstream starting in 6” clay near clean out and ending in 6” pvc before main run out of house. Did NOT reinstate downspout near garage customer will run above ground, city does not allow rain water into sanitary sewer.
Televised ducts under slab floor. Ducts are cardboard and spiral wound metal. Suggest spin casting cardboard then spray lining entire system with Duct Armor.
Televised ducts under slab floor. Ducts are cardboard and pvc. Cardboard needs to be spin cast mportared then the entire system should be spray lined with Duct Armor.
Televised sewer from outside clean out in front yard both downstream and upstream. 12ft downstream from cleanout there appears to be a whole house trap. There are a couple cracks downstream of the trap. Also televised from inside clean out in basement. There are heavy roots in the clay before it gets to the clean out outside. Will provide a proposal for lining from both inside from catch basin and from clean out.
2-18-2025: Televised sewer from 3” pvc stack clean out in basement to city main, all 4” cast to main (main runs between customer and neighbors house to left of house). Heavy roots used mini miller to clear root blockage. 45’ x 4” cast with 2 reinstates. Has newer interior drain tile, tvd all window well drains to bottom/ original drain tile all filled with debris at bottom. New drain tile does not tie directly into new pit, pit is perforated with holes drilled in pit. Plumber would need to re-do 3” pvc to 4” pvc near stack clean out and leave missions to remove 4” section to install liner from open pipe with new 4” pvc leaded in at floor/cast hub. ***CREDIT BACK $895 for tv and cleaning off lining proposal***
12-11-2024: measured sewer in preparation for lining from 6” pvc clean out on right side of house (5’11” deep) about 140’ to city main starting in pvc near clean out and ending liner at city main need to line into main and cut liner back to tap. 2-6-25 Inserted a 6” liner through the existing outside clean-out extending approximately 140 feet downstream ending at the connection to the city main. Reinstated one connection.
1/10/25 Milled cardboard airducts with picote. Cleaned all underground duct work in preparation of trenchless spincast mortar. 1/16/25 Applied trenchless spincast mortar to all cardboard airducts. Repaired and rebuilt furnace box and all register vents with trenchless spincast mortar. 1/21/25 Applied first application of duct armor to all underground ductwork and furnace box. 1/30/25 Applied second application of duct armor to all underground ductwork and furnace box.
Televised sewer from clean out in garage to main run leading out to city approximately 44ft. Line looks to be 6” clay and has roots and cracking. Suggest lining from clean out to pvc where it goes into the main run.
Cleaned all underground ductwork and furnace box in preparation of trenchless spincast mortar. 1/13 Applied trenchless spincast mortar to all cardboard airducts. Repaired furnace box and register vents using mortar as well. 1/17/25 Applied first application of duct armor to all underground ductwork and furnace box. 1/23/25 Applied second application of duct armor to all underground ductwork and furnace box.
Cleaned air ducts in preparation for trenchless spincast mortar. Applied spin cast mortar to all underground duct work. Rebuilt plenum and all register boots with mortar.
Did not televise the ducts, because the system has already been turned overhead.
Televised ducts under slab floor. Ducts are cardboard and metal. Will provide a proposal for spin cast mortaring then spray lining with Duct Armor.
Televised ducts under slab floor. Duct are concrete and metal. Suggest spin cast mortaring cardboard then spray lining entire system with Duct Armor duct lining material.