Response from Trenchless Innovations Inc.:
Thank you for your review, Dan! We are happy to hear you had a great experience with our team. Thank you for choosing us for your sewer lining service. We hope you are enjoying the benefits our lining process gives you!
i watched a little bit they were very professional ! I hope it works and lasts a long time !
Response from Trenchless Innovations Inc.:
Thank you for your review, David! We are happy you had a great experience with our team and we know you will love the cleaner, healthier air you'll now experience by having your ducts lined. Thank you for choosing Trenchless Innovations, we are grateful for your support!
Everyone on the team was great and I appreciated the honest and thorough explanation of everything
Response from Trenchless Innovations Inc.:
Thank you for taking the time to leave us a review, Dan! We are happy to hear you had a great experience with Bob and the team during your sewer televising. We appreciate your business and please reach out to us if you have any additional questions. Thanks again!
Cleaned and measured sewer in preparation for lining. Lined sewer from 6” pvc clean out in front yard 38’ upstream starting in 6” pvc near clean out and ending in 6” clay just before 4” pvc.
Under slab duct inspection service call. Used camera to inspect ducts. Ducts are made of concret transite but the fittings are starting to fail - lots of rust spotted. Recommended spin cast mortaring to repair. Provided estimate for duct armor to ensure proper duct lining.
Underground ductwork repair and ductwork resealing service call. Cleaned all underground ductwork. Applied first application of duct armor to all underground ductwork.
Ductwork video camera service visit. Televised ducts under slab portions of house. Ducts are concrete possibly Transite with Asbestos. Suggest spray lining to seal for possible radon and also encapsulate the concrete pipes.
Air duct inspection visit. Televised ducts under slab floor in lower level. Ducts are concrete with metal fittings. There was standing water in 2 pout of the 3 ducts. Recommended air duct repair service. Suggest regrading front of house and extending downspouts. After that the ducts should be spin cast mortared on the metal then spray lined with Duct Armor duct lining material.
Inserted a 6” liner through the existing outside clean out and continued downstream approximately 40' ending prior to the city main sewer line.
Televised sewer from Oslo and could not get past 35ft Rodded but could not get past that spot. Televised from Isco and got to same spot. Suggest digging to make repair at bad location then installing liner.
10-21-2022: installed 5’ spot repair liner 14’ downstream of clean out over break/ void in clay tile, took measurements for inversion lining (orange tape marks on camera)
We are cleaning the sewer and lining a 50’ section of 6” clay tile pipe that has heavy tree root growth at the clay tile pipe joints, lining through these joints with our seamless liner won’t allow the tree roots to grow back into the sewer and cause a sewer back up into the house!
We are sealing all the underground duct work in a slab home with our rubberized duct lining product.
We are applying the first of two applications of our rubberized duct lining material to the heavily rusted underground air duct system. The customer was experiencing heavy debris and sand throughout the home, but now the air ducts will be completely sealed. The air in the home will be safe for the customer to breathe.
We are cleaning all the underground duct work and applying our trenchless cast mortar to all the metal fittings, connectors, and plenum box in preparation for lining the entire underground duct work system with our duct lining product.
Televised sewer from outside clean out. Heavy roots aroung 50 - 60 ft out. Rodded sewer 90 ft to city main then televised to make sure roots were gone. Will provide quote for lining approximately 50 ft of sewer with a 30 ft remote start.
Applied our duct lining product to all underground duct work under a slab section of the home to prevent from rusting out and deteriorating also seal any leaky connections leaving a clean air flow into the home.
Televised ducts under slab floor. Ducts are concrete with metal connections and fittings. Plenum under furnace and the metal connections are rusting away. There was no standing water in the system but there were signs where water had been in the system. Suggest extending all downspouts away from the house. Two that are in the ground should be removed during the winter months and run above ground. After addressing the water issue the ducts should be spray lined with Duct Armor duct lining material.