1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for highland park, il


Job Locations
for highland park, il

Bob S.

Bob S. Job Checkin

Televised sewer from inside clean out but could only get about 60ft out due to heavy roots. Suggest lining sewer from a new clean out that will be installed in basement approximately 75ft to city main. Will provide proposal.


Bob S.

Bob S. Job Checkin

Televised sewer from catch basin in front of garage. Sewer back to trough drain is cracked. Sewer to main has heavy roots. Provide quote to line both lines.


Josh R.

Josh R. Job Checkin

Applied second application of duct armor to all underground ductwork and furnace box.


Josh R.

Josh R. Job Checkin

Today I performed ductwork restoration services at a residence in Highland Park, Illinois. The scope of work involved applying the initial coat of Duct Armor sealant to all underground duct runs as well as the interior of the furnace box itself. Duct Armor is a specialized elastomeric coating that seals and encapsulates duct surfaces to prevent moisture intrusion, inhibit mold growth, and improve airflow efficiency. Properly sealing and insulating ductwork is an important part of maintaining healthy indoor air quality and optimizing HVAC system performance. After allowing the first application to cure, a secondary coat will be applied to complete this duct rehabilitation project.


Josh R.

Josh R. Job Checkin

Applied trenchless spincast mortar to all underground ductwork and furnace box. Repaired and rebuilt furnace box and all register vents with hydraulic cement.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized and showing some signs of rust. The plenum is very rusted. Suggest spin cast mortaring and spray lining with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab portion of the house. Ducts are galvanized metal and are very rusted. Suggest spin cast mortaring the spray lining with Duct Armor duct lining material in order to restore ducts. Due to the size of the registers two locations will need to be opened up in order to allow mortar equipment to access the ducts.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor on lower level of house. Ducts are concrete with metal fittings. Suggest spin cast mortaring the metal connections then spray lining the concrete ducts with Duct Armor material to encapsulate the concrete pipes.


Bob S.

Bob S. Job Checkin

Duct lining application service call. Applied first coat of Duct Armor to all registers and duct runs.


Bob S.

Bob S. Job Checkin

Sewer inspection service call. Televised sewer from inside clean out. Could only push approximately 104ft due to configuration of clean out and the turns it made. Clay tile up to that point looks to be in good condition. Sewer repair recommended. Suggest installation of and outside clean out then re-televise for possible lining. Recommend Bills Plumbing for installation of clean out.


Josh R.

Josh R. Job Checkin

Televised and cleaned all underground ductwork. Coated all underground ductwork with duct armor and transite pipe in basement.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are mostly clay tile with the exception of one run that is metal. The one metal run is extremely rusted and deteriorated. The clay tile has debris at the joints. Suggest spin cast mortaring the system then spray lining with Duct Armor duct lining material. Customer has just recently installed drain tile around entire house to control any water issues.


Jim D.

Jim D. Job Checkin

We are applying the second application of our rubberized Duct Armor material to all of the underground asbestos transite air ducts. The air in the home will be environmentally safe to breathe.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work, and sealing the underground duct work, which is transite concrete pipe with metal connectors/ elbows, with our duct lining product.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are metal and are extremely rusted. Ducts should be spin cast mortared to restore the structure of the ducts then spray lined with Duct Armor duct lining material.