Customer needs to be rodded. Scheduled for R&P to rod tomorrow and video so we can quote for possible lining.
Inserted a 6” liner through the existing outside clean-out extending approximately 40 feet downstream to just before the city main.
Televised ducts under slab floor. Ducts are a combination of concrete and metal. There was some sand in the front bedroom duct and the plenum . was very rusted and deteriorated. Suggest rebuilding the plenum but the furnace would need to be removed because the water lines are in the way. After the plenum is repaired the ducts should be spray lined with Duct Armor duct lining material. Suggest TechOne heating to remove the furnace.
Ductwork video camera inspection. Televised ductwork underneath home slab. Discovered ductwork was in good shape and no repairs needed at this time.
Sewer lining repair service call. 6/2/23 Cleaned and measured line in preparation for lining. 7/5/23 Lined approximately 20’ of 6” sewer line upstream ending in 4” cast iron from outside cleanout. Lined approximately 10’ of 6” sewer line downstream from outside cleanout.
We are lining the sewer from outside two clean outs making the old clay tile sewer “like new” from the house all the way out to the city main!
Lining 6 inch clay sewer line from outside clean out to city main. Customer was having sewer backup from heavy root growth. Video inspection showed clay tile pipe was cracking.
We lined a sewer from an overhead stack clean out in the basement 70’ out stoping just before the second overhead tie in from the house sealing off the sewer where heavy tree roots would grow in through the joints and sealing a break in the 4” cast near the foundation wall where sewer water would seep back in/ towards house
Lined the sewer from an open hole near the city side walk out to the city main in the middle of the street which is about 20’ deep! Leaving the pipe like new pvc within the old clay tile pipe, with out needing to trench through the side walk or road saving a lot of restoration cost for the home owner.
Televised sewer for installation of liner.
Look at under slab ducts, getting water into basement where duct go through wall. Recommend lowing water table under slab.