1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for lombard, il

Rated 4.7 out of 5 stars based on 3 customer reviews

Excellent service!

The consultant answered all my questions. He did inspect every single duck of the property and explained me very clearly my options.


Response from Trenchless Innovations Inc.:

Mario, thank you for your kind words! We are delighted that you had a great experience with our team and that we provided you with the options available to you. Thank you for choosing Trenchless Innovations and please reach out if you have any other additional questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very pleased with the job quality, the responsiveness from everyone involved, and the courtesy throughout the entire process.

Very good experience.


Response from Trenchless Innovations Inc.:

Thank you so much for taking the time to share your experience with us, Clyde! We are delighted to hear you had are happy with the service our team provided you. Thank you for choosing Trenchless Innovations for your underground air duct lining! We hope you are enjoying the cleaner, healthier air in your home as a result. We appreciate your business!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied Customer

All the members of the Trenchless Innovations team were extremely helpful explaining the process and keeping me in the know of just how it was progressing. They were efficient in their tasks and courteous to me and careful to protect my home while doing the work. I would recommend Trenchless Innovations.


Response from Trenchless Innovations Inc.:

Thank you so much for this great 5-star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lombard, il

Bob S.

Bob S. Job Checkin

Ductwork video inspection service call. Televised ducts under slab floor. Ducts are concrete ducts with metal fittings that are very rusted. Suggest spin cast mortaring metal fittings then spray lining ducts with Duct Armor duct lining material. Suggest regrading in back of house to reduce water pooling in the back.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor on lower level of house. Ducts are concrete ducts with metal fittings that are rusted and deteriorating. There was moisture and standing water in 3 of 4 lines. There is a sump pit and pump installed. There is no drain tile and holes were just recently drilled in sides of pit. Suggest spin cast mortaring ducts on metal fittings then spray lining with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete with metal fittings that are rusted and allowing water and debris into the pipe. Suggest spin cast mortaring on the bottom level then spray lining the system with Duct Armor.


Kevin W.

Kevin W. Job Checkin

9-23-2024: Cleaned and measured sewer in preparation for lining from open hole in basement. Did NOT see and drain tile connection in 6” clay or at cast to clay found where existing tile ties into flood drain in middle of basement. 9-30-2024: lined sewer from open hole/ open pipe in basement 70’ downstream starting in 4” cast near foundation wall and ending in 6” clay near city main.


Bob S.

Bob S. Job Checkin

Televised sewer from clean out in basement approximately 70ft to city main. Customer will cut out pipe prior to us cleaning and measuring.


Bob S.

Bob S. Job Checkin

Provide estimate to line either 12ft or 70ft from open pipe in basement


Josh R.

Josh R. Job Checkin

Resprayed duct line from bathroom register. Duct armor washed away from prior rains. No water present in air ducts but water marks in bathroom line. Recommended replacing gutter near the bathroom and adding soil to flower bed to raise it. Resprayed all register boots.


Bob S.

Bob S. Job Checkin

Sewer video inspection service call. Televised sewer from outside clean out near sidewalk back to house. Sewer was not backed up at all but had heavy roots t the cast to clay. Pushed into cast iron and saw check valve that is buried in crawl space. Located additional overhead line that is where the main stack is running through that tees into this line just outside foundation wall. this line was all backed up due to roots. Duct outside to expose line approximately 6” deep. Cut a window on the cast iron then Rodded from there to open line. Completed sewer repair steps.


John R.

John R. Job Checkin

Sewer liner repair service call over multiple visits. 8-17-2023: Measured sewer line in preparation for sewer lining. Left job at 3:30 pm. 8-18-2023: installed 10’ spot repair liner from open hole were bottom of pipe was missing at open hole, also installed 5’ spot repair liner in section of pipe about 15’ downstream from open hole where bottom/sides of pipe were missing. Lined 5” cast sewer from open hole in shop area 104’ to 6” pvc pipe near manhole, reinstated 2 connections.


Josh R.

Josh R. Job Checkin

Ductwork cleaning service call. Cleaned all underground duct work. Applied first application of duct armor for ductwork sealing.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections that are severely rusted. Suggest spin cast mortaring metal fitting then spray lining ducts with Duct Armor duct lining material to encapsulate the concrete ducts. Homeowner had experienced a previous sewer line break and it got into the ducts.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete possibly Transite with asbestos with metal fittings and connections that are rusted. Suggest spin cast mortaring to restore structure to the metal then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with asbestos with metal fittings and connections. Metal distribution boxes are very rusted and need to be mortared but there is no access to them. Would need to open the floor in the family room then spin cast mortar from that point then spray line entire system with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily rusted underground duct work.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated metal underground duct work.