Jim D. Job Checkin

We are applying the second application of our rubberized Duct Armor material to all underground duct work. Customer was experiencing sand and debris throughout the home because of the heavily rusted air ducts. The deteriorated underground air ducts are now completely sealed.


Jim D.

Jim D. Job Checkin

We applied trenchless cast mortar to all deteriorated underground duct work to give pipes a strong structure. We are now sealing the air ducts with our rubberized duct lining material.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work and trenchless casting a new concrete pipe within the old weak/ rusted metal ducts to restructure the pipe leaving a solid pipe to work from in preparation for lining/ sealing the underground system leaving a nice efficient and clean air flow.


Jim D.

Jim D. Job Checkin

Rebuilding under slab duct work in preparation for Duct Armor sealant.


Bob S.

Bob S. Job Checkin

Video inspection of sewer from overhead clean out in basement. Catastrophic iron pipe is shifted and offset to the point where it needs to be excavated and repaired.


Kevin W.

Kevin W. Job Checkin

We cleaned the underground duct work, applied trenchless cast to all the metal fittings and connectors that were completely rusted out and rotted away to give them structure again, and finally we applied two applications of our duct armor product to encapsulate the transite pipe and seal the underground duct system.

We cleaned the underground duct work, applied trenchless cast to all the metal fittings and connectors that were completely rusted out and rotted away to give them structure again, and finally we applied two applications of our duct armor product to encapsulate the transite pipe and seal the underground duct system.

Kevin W.

Kevin W. Job Checkin

We cleaned all the underground duct work which consisted of transite pipe with metal connectors and elbows that were rusted away. After everything was cleaned we were able to go in and trenchless cast the entire underground system to give the pipe structure again. Then finally we were able to apply our duct armor product to encapsulate the system leaving a clean and sealed system.


Bob S.

Bob S. Job Checkin

Trenchless Innovations is performing their Trenchless casting method of repair on extremely deteriorated under slab air ducts. This method of repair will spin cast a new concrete pipe inside the old deteriorated pipe to restore the structural integrity of the pipe. Once this is done the ducts will then be spray lined with Duct Armor duct lining material. All this will be done with no destruction to the slab floor or loss of service to the homeowner.


Bob S.

Bob S. Job Checkin

Video inspection of under slab air ducts. Ducts are concrete with metal connections tees and elbows. All metal connections are severely rusted. Downspouts are dropping right next to the house and causing the water level under the slab to rise up into the ducts. Customer needs to extend all downspouts. After water issue is resolved the ducts should trenchless casted with mortar to restore structure to the pipes then spray line the ducts with Duct Armor Duct lining material.


Kevin W.

Kevin W. Job Checkin

Another one of the many condos we have televised in this subdivision and found the underground duct work was heavily rusted out. First we cleaned all the ducts of dirt, dust, and debris, then we applied our spin cast mortar to restructure the weak rusted metal. Finally we were able to coat and seal the underground ducts with our duct armor product leaving a clean air flow for the customer. Now the customer can take a break from having to dust and clean daily due to old ducts allowing dirt in!


Kevin W.

Kevin W. Job Checkin

Customer was getting water in the underground air ducts so we installed a sump pit and pump with a section of drain tile deeper than the duct work to eliminate water from getting into the system, after the water issues was resolved we applied spin cast mortar to all the underground duct work to give the weak rusted metal fittings some structure, after the spin cast mortar we applied two applications of duct armor to seal all the duct work leaving a clean hvac system for the air to flow through.

Customer was getting water in the underground air ducts so we installed a sump pit and pump with a section of drain tile deeper than the duct work to eliminate water from getting into the system, after the water issues was resolved we applied spin cast mortar to all the underground duct work to give the weak rusted metal fittings some structure, after the spin cast mortar we applied two applications of duct armor to seal all the duct work leaving a clean hvac system for the air to flow through.

Bob S.

Bob S. Job Checkin

Video inspection of underground air ducts showed water in ducts. Tested all drain lines and believe customer has a leak on their incoming water line

Video inspection of underground air ducts showed water in ducts. Tested all drain lines and believe customer has a leak on their incoming water line

Bob S.

Bob S. Job Checkin

Spin cast mortared to repair severely rusted and deteriorated galvanized elbows in the under slab ductwork.