Josh R.

Josh R. Job Checkin

Televised dryer vent from both outside by deck and inside. There is a section that is crushed down creating lint build up and not allowing proper airflow. There are no breaks or separations in the line.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily rusted underground duct work.


Bob S.

Bob S. Job Checkin

Under slab air ducts were galvanized spiral wound metal that were extremely rusted allowing white duct to enter into the house. Trenchless innovations applied a spin cast mortar to the ducts and plenum to restore the structure then spray lined the ducts with two applications of Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work which is a spiral wound galvanized pipe that is pvc coated and is heavily rusted away and deteriorated, so are applying our trenchless cast mortar to restructure the weak metal, then applying two applications of our duct lining material to all the underground duct work leaving a solid, sealed, and clean pipe!


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily rusted metal underground duct work.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are cleaning all of the underground asbestos transite air ducts with our special high powered vacuum. After all the debris from the air ducts is cleared, we are going to encapsulate the pipes with our rubberized duct lining material. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily rusted underground duct work. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Jim D.

Jim D. Job Checkin

We are applying the second application of our rubberized Duct Armor material to all underground duct work. Customer was experiencing sand and debris throughout the home because of the heavily rusted air ducts. The deteriorated underground air ducts are now completely sealed.


Jim D.

Jim D. Job Checkin

We applied trenchless cast mortar to all deteriorated underground duct work to give pipes a strong structure. We are now sealing the air ducts with our rubberized duct lining material.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work and trenchless casting a new concrete pipe within the old weak/ rusted metal ducts to restructure the pipe leaving a solid pipe to work from in preparation for lining/ sealing the underground system leaving a nice efficient and clean air flow.


Jim D.

Jim D. Job Checkin

Rebuilding under slab duct work in preparation for Duct Armor sealant.


Bob S.

Bob S. Job Checkin

Video inspection of sewer from overhead clean out in basement. Catastrophic iron pipe is shifted and offset to the point where it needs to be excavated and repaired.


Kevin W.

Kevin W. Job Checkin

We cleaned the underground duct work, applied trenchless cast to all the metal fittings and connectors that were completely rusted out and rotted away to give them structure again, and finally we applied two applications of our duct armor product to encapsulate the transite pipe and seal the underground duct system.

We cleaned the underground duct work, applied trenchless cast to all the metal fittings and connectors that were completely rusted out and rotted away to give them structure again, and finally we applied two applications of our duct armor product to encapsulate the transite pipe and seal the underground duct system.

Kevin W.

Kevin W. Job Checkin

We cleaned all the underground duct work which consisted of transite pipe with metal connectors and elbows that were rusted away. After everything was cleaned we were able to go in and trenchless cast the entire underground system to give the pipe structure again. Then finally we were able to apply our duct armor product to encapsulate the system leaving a clean and sealed system.