1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Local Reviews
for park forest, il

Rated 5.0 out of 5 stars based on 2 customer reviews

Great 👍

Professional


Response from Trenchless Innovations Inc.:

Thanks for taking the time to share your experience with us, Davis! We appreciate your business and we are happy we could help uncover the issues with your underground air ducts. If you have additional questions, please don't hesitate to call our office at 708-758-5070. Thanks again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service Awesome Price

Fantastic moo


Response from Trenchless Innovations Inc.:

Thanks for your review, Ronald! We are happy to hear you had a great experience with us. Thank you for choosing us for your air duct lining - you're on your way to cleaner, healthier air! Happy Holidays to you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for park forest, il

Josh R.

Josh R. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal elbows. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the first application of duct armor to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily deteriorated underground cardboard air ducts.


Josh R.

Josh R. Job Checkin

We are applying our Trenchless Cast Mortar to all of the heavily deteriorated underground cardboard air ducts. This process will give the air ducts a strong concrete like structure.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. There was no standing water in ducts at time of the inspection but there were water marks indicating prior water in system. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized metal ducts. There are two locations where the pipes are collapsed and need to be dug up to be fixed. Once that is done the remainder of the system should be spin cast mortared then spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. The cardboard is showing signs of water contact and the plenum is rusted on the bottom and sides. Suggest spin cast mortaring the ducts to restore and ensure proper structure then spray lining ducts with Duct Armor duct lining material to provide a clean and healthy breathing environment.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground cardboard air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Kevin W.

Kevin W. Job Checkin

We are repairing the underground duct work in a slab home cardboard ducts that were molded and deteriorated, applying our trenchless cast to restructure and line with our rubberized duct lining material.


Jim D.

Jim D. Job Checkin

Encapsulated all deteriorated underground duct work with our duct lining material. The air in the home is now environmentally safe to breathe.


Kevin W.

Kevin W. Job Checkin

Our customer was getting a musty smell coming from the underground air ducts so we applied our duct lining product to all the underground duct work under the slab home to seal the underground system and line the existing duct work.


Kevin W.

Kevin W. Job Checkin

Applied trenchless cast to all deteriorated underground duct work to give pipe a strong structure.


Kevin W.

Kevin W. Job Checkin

Encapsulated all deteriorated underground duct work with our rubberized duct lining material.


Kevin W.

Kevin W. Job Checkin

Applied Trenchless cast to all deteriorated underground duct work to give it a strong structure. Encapsulated all underground duct work with our rubberized duct lining material.


Jim D.

Jim D. Job Checkin

Televised sewer line from inside clean out stack. A section of the pipe is collapsed, causing water to leak out of pipe and under the customers home.