Homeowner is having an outside clean out installed by his plumber. Explained where it should be located and that a straight tee should be installed to allow us to go both ways will provide a quote for lininig approximately 50ft from newly installed clean out to city main
Televised sewer from clean out that was found in the basement. Cast iron looked in good condition. Clay tile had roots at many joints. It looks like there may be a hole in the bottom of the city main because the camera was unable to push into and around the city main sewer. the city main sits in the parkway.
Televised sewer from overhead clean out in basement. Clean out is 3” copper then goes to 4” cast and then to 6” clay tile outside. Cast is slightly scaled but is not causing any blockages at this time. Clay looks to be in good condition.