Televised ducts under slab floor. Ducts are a combination of PVC and metal ducts that are allowing sand to enter the system where the metal is rusting. Plenum under furnace is also very rusted. Suggest spin cast mortaring metal then spray lining entire system with Duct Armor duct lining material.