Trenchless Innovations has been great from the front office to the team in the field. Small residential project was treated as if was large contract. Stayed and problem solved a tricky ‘small’ project until it was 100% addressed, including a second trip. They saved us from having to complete very invasive work in the exterior and interior of the home. Their professionalism and shared sense of urgency was greatly appreciated. Fantastic crew, work product and support team! Highly recommend Trenchless Innovations!


Response from Trenchless Innovations Inc.:

Kevin, thank you for your thoughtful review! We are happy that you had a great experience with our team and that we could thoroughly address and solve your sewer issues without having to dig the exterior or interior of your home. We appreciate your business and your recommendation. Please don't hesitate to reach back out if you ever have any questions regarding the work we have completed for you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hammond, in

Bob S.

Bob S. Job Checkin

Applied a second coat of Duct Armor to all registers, duct runs, and the plenum. This application ensures a more durable and long-lasting seal, enhancing the structural integrity and efficiency of the ductwork. The coating also helps prevent future corrosion and leaks, providing better indoor air quality and improved HVAC system performance. After the application, we conducted a thorough inspection to ensure complete and even coverage, confirming that all areas were adequately treated and protected.


Bob S.

Bob S. Job Checkin

Performed the initial application of Duct Armor to all underground ductwork. The process began with a thorough cleaning of the ducts to remove any debris and rust. Then, using specialized spray equipment, applied the first layer of Duct Armor. This material provides a durable and protective coating, effectively sealing the ducts to prevent leaks and corrosion, and enhancing the overall efficiency and longevity of the duct system.


Josh R.

Josh R. Job Checkin

Televised and cleaned all underground ductwork. Installed UV spot repair patch in offset line from furnace box. Applied trenchless spincast mortar to all elbows and connections. Repaired plenum box with hydraulic cement.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete with metal fittings that are allowing sand to enter the system. Suggest spin cast mortaring metal then spray lining system with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings that have rusted out. Suggest spin cast mortaring joints then spray lining system with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Reid televising but could not get camera into ducts because they are too small on the baseboard and the camera will not go into the pipe. There is no a-coil but could not get front panel off because the furnace is sitting on top of front panel. Suggest having their HVAC person modify the front panel then have us come back out to TV.


John R.

John R. Job Checkin

Looked at baptismal fountain for possible epoxy coating, no access to coat from underneath our epoxy is not an option.


John R.

John R. Job Checkin

Televised sewer from clean out next to back door of building but could not get past 30ft. Televised back to building from 6” clean out in parking lot and saw connection from 4” kitchen line. Hooked up this line with camera and could not get back to clean out due to heavy grease. Rodded 4” line from clean out out to main line and broke up grease and go sewer running again. Televised from 4” clean out by back door all the way to city main approximately 126 ft. Sewer is open with no breaks.


John R.

John R. Job Checkin

Installed 8’ spot repair liner from stack in basement towards front of house downstream starting just after possible floor drain tie in on left side of pipe and ended liner just before kitchen tie in on left side of pipe(outside the house), lined over wye connection from stack in back of house and also floor drain near washer/dryer, reinstated wye from stack in back of house and floor drain near washer/dryer. Applied 3 applications of spraypoxy from stack in back of house to patch liner where we reinstated.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections. Ducts are getting sand in through the joints and the plenum. Suggest spin cast mortaring joints and metal then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections where sand is entering into the ducts. The plenum is also rusted with holes. Suggest spray lining to encapsulate the concrete pipes and stop the sand.


Kevin W.

Kevin W. Job Checkin

Cleaned 5’ section of 4” cast iron/lead toilet collar and epoxy coated 5’ section of cast/lead to achieve 3mil thickness from tee dropping down stack/ up vent back to toilet collar. *** send copy of invoice via mail do not have email.


Josh R.

Josh R. Job Checkin

We are applying our spin cast mortar to all of the heavily rusted connections and elbows in the underground duct work.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground duct work.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.