Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections where sand is entering into the ducts. The plenum is also rusted with holes. Suggest spray lining to encapsulate the concrete pipes and stop the sand.
Cleaned 5’ section of 4” cast iron/lead toilet collar and epoxy coated 5’ section of cast/lead to achieve 3mil thickness from tee dropping down stack/ up vent back to toilet collar. *** send copy of invoice via mail do not have email.
We are applying our spin cast mortar to all of the heavily rusted connections and elbows in the underground duct work.
We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground duct work.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.
Televised ducts under slab floor. Ducts are concrete with metal couplings allowing sand into the system. Suggest spin cast mortaring metal then spray lining the system with Duct Armor duct lining material. Suggest running downspouts out further.
We are cleaning all the underground duct work, our customer has sand/ dust entering the underground duct work through the rusted metal connectors and elbows, allowing the sand/ dust to blow all over the house, we are applying our trenchless cast to restructure all the weak rusted metal and also spray lining/ sealing the first of two applications to the entire underground duct work system with our rubberized duct lining product
Televised ducts under slab floor. Ducts are concrete with metal connections and fittings that are rusting and allowing sand into the system. There was no water in the system but the gutters and downspouts need to be replaced and extended from the house. Suggest spin casting the metal connections and then spray lining the system with Duct Armor duct lining material.
Cleaned all underground duct work. Encapsulated all deteriorated underground ductwork with our duct lining material.
Video inspection of sewer from an inside clean out. Sewer has a break located near the sidewalk approximately 6ft deep. Suggest digging down to repair the break and the lining from that point to the city main sewer.