Conducted sewer video inspection at residential property in Hobart. Client reported recurring backups in basement fixtures despite multiple routine cleanings by previous service providers. Deployed high-definition sewer camera from basement cleanout access point. Line is 6-inch clay pipe transitioning to city connection at approximately 65 feet. Inspection revealed multiple issues: significant root intrusion at 18 feet and 43 feet from access point penetrating through pipe joints; partial collapse at 38 feet creating approximately 30% restriction in flow capacity; and improper grade between 50-60 feet creating standing water and debris accumulation. Notable mineral buildup observed throughout system indicating history of water treatment discharge. Total line length to city connection measured at 72 feet. Provided customer with comprehensive digital recording of inspection with professional narration identifying all deficiencies. Recommended trenchless pipe lining as most cost-effective


Josh R.

Josh R. Job Checkin

Performed a televised inspection of the underground air ducting to identify any damage or gaps for a customer in Hobart, IN. After the inspection, the ducts were thoroughly sealed to prevent air leaks and improve system efficiency. This sealing process stops air loss, protects against moisture and contaminants, and enhances airflow. Sealing the underground ducts also prevents dirt, mold, and pests from entering, ensuring cleaner air quality and better HVAC performance. The televised service ensures precise detection and targeted repairs.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are PVC ducts with metal fittings. There was water in the lines on the right sid of the house. There was also a sump pump in the plenum. Downspouts need to be corrected and grading is not correct. Need to raise pitch by house for patio in courtyard.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are pvc coatefc metal ducts. There is standing water in the plenum and main duct run. There are changes outside with downspouts and grading that need to be made. After the water is resolved then the ducts should be spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections. Sand entering into ducts from the metal fittings. Suggest. Spin cast mortaring metal fittings then spray lining ducts with Duct Armor duct lining material. Make senior citizen discount.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are pvc coated metal. Sand is being drawn int the pipe through the joints. Suggest spray lining with Duct Armor duct lining material.