Job Locations
for draper, ut

Spencer M.

Spencer M. Job Checkin

Came too check too see if furnace was sized correctly for the home. Load calculation shows sizing is correct. What I found wrong is the temperature difference between return air and supply is too low. Along with the airflow is not setup correctly. Will have a technician come too do proper setup gas pressure and airflow.


Spencer M.

Spencer M. Job Checkin

Came too check too see if furnace was sized correctly for the home. Load calculation shows sizing is correct. What I found wrong is the temperature difference between return air and supply is too low. Along with the airflow is not setup correctly. Will have a technician come too do proper setup gas pressure and airflow.


Tyler B.

Tyler B. Job Checkin

I responded to a no cool call. Upon inspection I found that the fan motors bearing are seized. The system is from 1999, I recommended replacement over repair but Sean wanted to go ahead with the new motor and agreed to pay the after hours fee for the parts house to get the motor. When I returned to out the motor in I found that the fan blades were rusted to the motor and I was unable to get them off. Sean agreed to replacing the blades as well, i will have to call around tomorrow to get the blades but have collected half of total today. 9-9 I returned today to install fan motor and blades. The unit is up and running properly now. AC was running when I left.


Tyler B.

Tyler B. Job Checkin

I responded to a no cool call today. Tenant stated that the fan motor was no turning on but when he pushed the blades with a screw driver the motor started up. When I arrived the system was off, i asked the tenant to turn the breaker back on as the disconnect is locked shut. When the power was turned back on the system kicked on just fine. I took amp measurements and no thing was over amping. When I took the corner panel off everything was covered in lint do to the dryer exhaust being right next to the condenser. I tested the capacitor and it was reading just fine. I tested the thank motor and it was reading high resistance in the windings. When the winding start reading such high resistance they will begin to heat up and eventually melt and brake the connection needed. Along with the winding an audible clicking can be heard coming from the motor. I believe this is from the bearings inside the fan motor. I believe that they are what it causing the high resistance in the windings and w


Spencer D.

Spencer D. Job Checkin

Complete AC tuneup replaced filter and humidifier pad. Sign customer up on Western savings club


Spencer D.

Spencer D. Job Checkin

Cleaned condenser coil and removed dirt from bottom 4 inches of coil. System is working however may need to be replaced. System is almost 18 years old and showing age. Customer will pay over the phone with the office


Spencer D.

Spencer D. Job Checkin

Replaced dual capacitor and contactor. System is running and house is cooling upon departure.


Ryan H.

Ryan H. Job Checkin

Thermostat said low battery. Customer was afraid of changing them herself. Installed 2 new customer supplied AA batteries. No trip charge because we don’t know if it said low battery the last time we were here.


Tyler H.

Tyler H. Job Checkin

Installed new 90% modulating Furnace, evaporator coil, and inverter condenser. We set furnace on a new box and installed an April air 1510 filter rack. We updated the gas line by adding a drip leg. We installed a plug/switch combo. Make sure that the furnace and coil head slope and ran new drains. We installed a new air scrubber in the supply. We installed an ecobee thermostat. We did not need to set gas pressures because the gas valve sets it for itself. On the outside we set the condenser on a new pad and leveled it with gravel. We flush the line set with RX 11. We pressure tested the system at 400 psi and then vacuum down the system down to 500 µm both tests were good and the system has no leaks. We kept the old disconnect box but ran a new AC web with a 30 amp breaker to protect the system. We weighed in the charge based on the amount of wine set there was. Both heating and cooling functions works properly while testing it on the ecobee thermostat. We were able to help the custome


Wesley D.

Wesley D. Job Checkin

System not coming on at all. No air coming from the vents. System power switch on the side of the furnace was shut off. Turn it on and system came on. Tested temp split and had a 20 degree temp split. Recommended 18-22 degrees difference. Recommend tune ups to be done on the systems and filters to be changed more often. Systems running when i left.


Ryan H.

Ryan H. Job Checkin

AC not working. Furnace was running but outdoor unit was not doing anything. Found that the capacitor inside the AC had gone bad. Installed new dual run capacitor. AC appears to be running now. Recommend customer change the filter. Customer signed up for WSC (western savings club) maintenance plan. We will return in the fall for a furnace tuneup and then again next spring.


Ben N.

Ben N. Job Checkin

The 2008 tempstar not working. Condenser fan motor broken. Contactor has pitting. Today replaced filter, fan motor and contactor, and uv air scrubber bulb.Ac has 23 degree tempsplit. It was running when I left.


Taylor G.

Taylor G. Job Checkin

Came out for full system tune up. System is a 2018 Lennox. Found there was no hard start kit on condenser this can help prolong life of ac. Found capacitor for outdoor unit is testing at a 11% over. This cannot exceed 5%. Found blower wheel need to be cleaned. Found no other issues with the ac today see health report. Furnace tune up found all electrical components are testing properly and working properly. Found no cracks in the heat exchangers. Found the furnace is burning clean. Found no co in supply duct work. Found no issues with furnace today, see health report card. System was working properly when I left the call. Wasn’t able to finish haven install today because of software issues Jackie will get back to us if I need to return to help finish the setup. 60 full full system tune up per Ryan.


Gabriel B.

Gabriel B. Job Checkin

I performed an AC tune up on a 2016 Goodman system. The system is working properly. The condenser coil outside is building up some dirt it could use a cleaning next season. The capacitor is testing below factory specs. And it could use a Hard start kit. See health report card for more details.


Gabriel B.

Gabriel B. Job Checkin

I performed a furnace tune up on a 2006 Armstrong system. The system is working but is not in a good shape. The temperature split is bad the heat exchanger is very rusted, signs that is been overheating for quite a while. I adjusted the gas pressure from 3.49 to 2.08 to bring the supply temperature from 190F to 169F. I checked for CO and there is no CO in the supply ducts. I started a furnace tuneup on 2016 Amana system but it has a bad inducer motor. I need to find and order one. I’ll comeback to finish this tuneup once I have the part. I replaced the inducer motor under warranty and performed a furnace tuneup. The system is working properly with no concerns at this. See health report card for more details