seth p.

seth p. Job Checkin

Back of the building system servicing the shop and the loft is very low on refrigerant running at 34 PSI suction in emergency override cooling mode and holding 125 psi when turned off System required 66 oz of new r410a to achieve an acceptable running pressure with all four systems and emergency override cooling mode. Current running refrigerant pressures are 130 and 362 Due to the complexity of the system ultraviolet dye is recommended with a recharge to positively identify the location of the refrigerant leak Recommend follow up ultraviolet dye leak search on 4 indoor head units in 2-4 weeks


seth p.

seth p. Job Checkin

2012 water furnace Envision nsv042 system is running in very good condition. Homeowners only concern is corrosion on multiple fittings associated with the hot water generator copper lines. Water furnace branded Emerson touch screen thermostat is in good condition with no corrosion or battery lights Visible corrosion buildup on the water lines does indicate a leak at some point in time and possibly a continuous long-term leak. recommend plumbing company replace the damaged fittings and shut off valves. Water flush and power flush the drain system, run test system refrigerant pressures at 126 PSI suction with 14 superheat at 57° Ground loop water pressure is stable at 18psi and in range with a minimum 15 requirement. Air filters are on schedule with homeowner and appear to be in like new condition Humidifier operation is questionable and bypass air flow damper was closed today. Controls were not adjusted All equipment is clean safe and ready for the remainder of Summer


Graham M.

Graham M. Job Checkin

**Incomplete** 7-23-26 6 x indoor mini split head chemical bib cleanings including full disassembly with blower wheel removal 5 x indoor drain pump motor replacement Ductless repairs Two indoor head units need pump replacement One indoor head unit needs full cleaning One condenser on the roof needs cleaning Office staff will contact Ron to reschedule the final repairs (2 ppl 3 hrs) Pumps are on site, cleaning supplies are in Seth's truck


seth p.

seth p. Job Checkin

2005 water furnace premier, pressurized closed loop system Upon arrival the system was working in good condition in cooling mode with a regular work order for general seasonal maintenance Initial inspections and minor maintenance cleaning in the electrical compartment discovered loose high voltage wiring arcing multiple times during the inspection. While searching for the cause of the electrical noise the integrity of the water furnace premier control board was compromised and the system shut down and would not reinitialize the compressor operation Install replacement water furnace premier control board from service stock Complete all the general duties of the maintenance including drain flush, minor maintenance air dusting and cleaning, filter rotation provided by homeowners, ground loop pressure testing, cooling mode operation testing Considering the age the equipment is running in very good condition All wiring in the electrical compartment has been inspected and secured. The


seth p.

seth p. Job Checkin

Perform misc repairs and cleaning on Mitsubishi ductless units. Notes: These repairs do not address any possible communication issues that the owner has described to the technician. There is no guarantee that the condensate pumps provided by owner will last any certain amount of time. Rebuild mini split drain manifold in shop mechanical room Second floor east bedroom system replace condensate drain pump in the wall and perform wall mounted indoor head cleaning with blower wheel removal. Clean East unit condenser


Jason D.

Jason D. Job Checkin

Replaced loud Daikin ac under warranty


Nate G.

Nate G. Job Checkin

Got readings with d checker


seth p.

seth p. Job Checkin

Two multi-head systems each containing four indoor head units and one outdoor unit. Owners are very concerned with the improper installation of the equipment that may result in a lawsuit against the installing contractor or general contractor. Today's inspection test run and minimal disassembly for test running has has concluded with several results. 1- The drain line manifold in the shop mechanical room is higher than the wall mounted units and will not drain upward to go over a wall.. Even with the assistance of Blue diamond Maxi pump the pressure of a 2-in manifold 4 ft tall holding water cannot be overcome by the pump pressure and is creating water overflowing and a leakage issues at every head unit in the building. The drain line terminations from each pump need a non-pressurized gravity reservoir or drain to spill into to prevent any back pressure of water and/or sludge buildup. Owners have eight new blue diamond maxi pumps on site and would like every pump replaced because


Nate G.

Nate G. Job Checkin

Using Daikin D checker to record data on a Daikin Fit AC system.

Using Daikin D checker to record data on a Daikin Fit AC system.

Nate G.

Nate G. Job Checkin

Took Compressor blanket off and recorded video of excessive noise being produced.


Nate G.

Nate G. Job Checkin

diagnostic on a Daikin Fit heatpump. Compressor is noisy.

diagnostic on a Daikin Fit heatpump.  Compressor is noisy.

seth p.

seth p. Job Checkin

Wifi-enabled Honeywell Vision Pro 8000 touchscreen thermostat upgrade Cheshire Road Sunbury, OH 43074

Wifi-enabled Honeywell Vision Pro 8000 touchscreen thermostat upgrade
Cheshire Road
Sunbury, OH 43074

Wes  S.

Wes S. Job Checkin

Water Furnace 5 series installation near Delaware.

Water Furnace 5 series installation near Delaware.