Brandon P.

Brandon P. Job Checkin

Did not find any issues that would cause a breaker to trip. Normal operation Amp draw is 11.4amps and startup Amp draw is 26.4 amps. Run capacitor is reading within spec. Stopped and started hnit multiple times to see if breaker would trip. Breaker did not trip while on site. Homeowner mentioned that electricians were there recently and checked for any loose connections and "cleaned the contactor contacts" but the contactor looks untouched due to dust on the contactor plastic housing not being disturbed. Homeowner said that the breaker has not tripped since the electricians were there. It is possible that if there were a problem, that the electrician may habe inadvertently fixed the issue while performing diagnostics or just tightening everything. Matt also asked about the thermostat possibly being in sunlight. Thermostat was not in sunlight while on site, and the closest window in the master bed was covered with closed blinds. Large windows in living room could possibly allow sun to

Did not find any issues that would cause a breaker to trip. Normal operation Amp draw is 11.4amps and startup Amp draw is 26.4 amps. Run capacitor is reading within spec. Stopped and started hnit multiple times to see if breaker would trip. Breaker did not trip while on site. Homeowner mentioned that electricians were there recently and checked for any loose connections and "cleaned the contactor contacts" but the contactor looks untouched due to dust on the contactor plastic housing not being disturbed. Homeowner said that the breaker has not tripped since the electricians were there. It is possible that if there were a problem, that the electrician may habe inadvertently fixed the issue while performing diagnostics or just tightening everything. 

Matt also asked about the thermostat possibly being in sunlight. Thermostat was not in sunlight while on site, and the closest window in the master bed was covered with closed blinds. Large windows in living room could possibly allow sun to

seth p.

seth p. Job Checkin

Initial inspection found the 40 amp circuit breaker in the main panel in the basement in the tripped off or "never" turned on position in the middle. Testrianol equipment and heat pump mode heating and heat pump mode cooling. Refrigerant pressures are perfect in cooling mode and within specs in heating mode. Heat pump heating mode 101° f, heat pump cooling mode 47°f Inspect all control wiring inside and outside, confirm correct setup on furnace blower control board and Honeywell vision pro 8000 advanced setup 40 amp circuit pulling 13.7 at the breaker ***Electrical breaker appears warm to the touch and should be ambient temperature. Recommend electrician inspect or replace the heat pump breaker


Graham M.

Graham M. Job Checkin

See Notes


Nate G.

Nate G. Job Checkin

Installed a propane (LP) conversion kit on a trane run-tru 2 stage 96% efficient gas furnace. Commissioned the heat pump, checked charge and set airflow. This is a dual fuel system.

Installed a propane (LP) conversion kit on a trane run-tru 2 stage 96% efficient gas furnace.   Commissioned the heat pump, checked charge and set airflow.   This is a dual fuel system.

Chris M.

Chris M. Job Checkin

Aprilaire Media Filter Installed in a New Construction house.

Aprilaire Media Filter Installed in a New Construction house.

Chris M.

Chris M. Job Checkin

Trane Furnace Installed in a New Construction house.

Trane Furnace Installed in a New Construction house.

Gregory N.

Gregory N. Job Checkin

Range vent

Range vent