Performed heating p.m. on oil furnace. Brushed and vacuumed. Replaced oil filter, nozzle, and strainer. Washed air filter. Started furnace, the furnace did not start and was not off on reset. Checked primary control. The relay was pulled in but not sending power to the burner. Touched the reset button and it started. Cycled power and the same thing happened. The control is bad. Replaced the primary control. Started and checked the operation. System is operating properly.