Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter. Replaced with company supplied Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps Chemically cleaned evap coil due to high level of dust and debris buildup. Need to purchase correct filter size which is 20x22x1 Recommend returning to preform a deep chemical cleaning of the condenser coil due to high levels of lint and debris buildup. Call to schedule after the dryer vent has had a trap added or has been diverted. The buildup could lead to issues with the unit if not taken care of.