18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for chandler, az

Rated 4.9 out of 5 stars based on 36 customer reviews

Great service, explained repair, dependable, prompt

Wonderful repair service, repair explained, warranty

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!

Highly recommend this company. Same day friendly service.


Response from Affordable Appliance Repair:

Laura, Thank you so much for taking the time out of your day to let me know how the company performed for you, it is greatly appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Dryer repair

Great service, very knowledgeable, very friendly. Fast repair

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ice Maker

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nick may be able to fix anything!

Within in 30 minutes of each other, my washer and dryer both died. I was all for just getting new ones, but my husband said we should really call an appliance guy. I humored him and called. When Nick arrived I said quietly, out of my husband’s earshot, best answer you can give me, I need a new washer/dryer. I was shocked, Nick quickly diagnosed, shared a plan and price and got to work! He was able to fix both, like new. Asked if he knew anything about dishwashers. He headed over to the dishwasher, again, diagnosed, shared a plan and price and we agreed it was time to get a new one. It was pretty amazing watching him work proficiently on multiple types of appliances. Also talking with him, I learned that he knew the idiosyncracies of specific makes and models. He was smart, efficient and pleasant. Highly recommend Nick!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service with a fair price

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and reliable.

I've used Affordable Appliance Repair a few times. They are always responsive and timely. I rent and remodel homes and having companies like this one that you can trust and count on to show up are very important. Thanks again for another job well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chandler, az

Daren O.

Daren O. Job Checkin

CONCERN: Customer reports Garbage disposal is not working. CAUSE: Garbage disposal breaker tripped. CORRECTION: RE-Set Garbage disposal breaker and cleared debris. tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. CORRECTION: Replaced and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTIO


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN Customer reports refrigerator evap fan makes noise. CAUSE: Found temp thermistor not making contact with evap. Causing ice buildup around evap fan. CORRECTION: cleared ice buildup around fan. Re installed thermistor correct on evap coil. tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of debris, operation now normal. Unit will need 24hrs to thaw ice around fan. CLEANED COILS TOO


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports BOSCH dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports SAMSUNG dryer is making a loud noise. Model DV48H7400WA2 CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports SAMSUNG dryer is making a loud noise. Model DV42H5200EW/A3 CAUSE: Found dryer idler pulley failed and rear lower drum support. CORRECTION: Replaced dryer idler pulley, rear lower drum support and tested, operation now normal.