CONCERN: Customer reports refrigerator is not working like it should. CAUSE: Found evaporator leaking freon. CORRECTION: Replaced evaporator and receiver dryer, checked for leaks and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

Bell/I60 in El MIrage Arizona CONCERN: Customer reports GE Refrigerator is not cooling properly. Model DFE29JSDASS DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. NOTE: Also Clean condenser coils and Replaced condenser fan motor


Carlos V.

Carlos V. Job Checkin

Bell/I-60 In El Mirage Arizona CONCERN: Customer reports GE Model DFE29JSDASS Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. NOTE: Also Clean condenser coils and Replaced condenser fan motor


Christopher M.

Christopher M. Job Checkin

Oven door needing put on. Peoria/El Mirage Reattached oven door back on oven.


Christopher M.

Christopher M. Job Checkin

Reverse doors on washer and dryer Peoria/Dysart Installed washer door on opposite side of washer.


Christopher M.

Christopher M. Job Checkin

Washer water valve