18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for fountain hills, az

Rated 4.8 out of 5 stars based on 6 customer reviews

Great service, great communication and timely service.....thank you Josh!

Excellent experience..... no more issues with my ice maker! Thank you Josh!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

service guy was fast and good.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional excellance

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very satisfied with service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable

Dave was courteous and experienced

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fountain hills, az

David R.

David R. Job Checkin

CONCERN: Customer requests installation of prepurchased broil element. CORRECTION: R&R oven from wall to replace customer purchased broil element and tested. CONCERN: Customer reports drain compactor is not working. CAUSE: Found screw missing from start switch bracket. CORRECTION: Replaced missing screw and tested. Operation now normal.


Josh  L.

Josh L. Job Checkin

Washer has Venturi effect. re positioned hose and tied in place. Unit operation normal. CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Josh  L.

Josh L. Job Checkin

CONCERN: Customer reports LG ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Josh  L.

Josh L. Job Checkin

CONCERN: Customer reports SAMSUNG Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the defrost or fridge fan. Cause of failure found ADC main control board shorted at the output line voltage. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports dryer is making a tapping noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN Customer reports refrigerator drawers keep popping out. CAUSE: Found broken support. CORRECTION: Replaced support and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports that the dishwasher is not working. DIAGNOSTIC AND CAUSE: Found dishwasher pump/rotor failed. CORRECTION: Replaced dishwasher rotor assembly and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports washer is very noisy in spin cycle. CAUSE: Found washer belt coming apart and glossed, and motor pulley caked with burnt on belt residue. CORRECTION: Replaced belt and motor pulley and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal CONCERN: Customer reports washer has damage at top of tub. CORRECTION: Replaced tub cover and tested, operation now normal.


Nick H.

Nick H. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. CORRECTION: Replaced and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION.


David R.

David R. Job Checkin

CONCERN: Customer reports Glass Cooktop left front burner is not working CAUSE: Found burner element failed. CORRECTION: Replaced and tested, operation now normal. NOTE: Burner element receptacle is in good working order at the time of inspection. Infinite switch is performing as designed at the time of inspection. WARRANTY: 1 Year PARTS AND LABOR Unless otherwise stated on this document. CONCERN: Customer stated oven door is not closing properly. CAUSE: Found oven door hinges failed. CORRECTION: Replaced door hinges and tested. Operation now normal.


Michael H.

Michael H. Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.Maytag Model MFI2569VE is not cooling Shea/Fountain Hills


Michael H.

Michael H. Job Checkin

Fase7021nw0 Frigidare dryer E64 code. (FH) CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Michael H.

Michael H. Job Checkin

Icemaker not working. Shea Blvd/Crestview Dr. CONCERN: Customer reports ice maker is not making ice. CAUSE: Tested water supply lines and water valve operation, Tested for proper voltage to the ice maker and inspected freezer for proper temperature. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


David R.

David R. Job Checkin

Refrigerator not working. CONCERN Customer reports refrigerator makes a noise when dispensing water, ice maker is not working, and is overdue for maintenance. CAUSE: Found filter not in all the way. CORRECTION: Replaced filter with customers part and tested. Operation now normal. Removed and inspected/cleaned ice bucket and turned ice maker on, and cleaned coils.