18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for gilbert, az

Rated 4.9 out of 5 stars based on 24 customer reviews

Great Service


Response from Affordable Appliance Repair:

Ashley, Thank you for taking the time to let other know how we did for you. I is greatly appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest service

Service Tech was knowledgeable and honest. I’ve used this service before and they are consistent. I recommend them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!! And great repair!!

Such a nice serviceman and fast to fix our problem!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Came out same day and knew exactly what was wrong. Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Refrigerator repair

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exactly what i wanted

'Steve' provided excellent communication, and kept in the loop the whole time...this is how i expect every service i pay for to perform...well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Spencer did a great job in repairing our washing machine, and we would use them again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Highly Recommend

Spencer repaired our washing machine in 30 minutes and also gave some helpful hints. All around great service. I highly recommend Spencer and Affordable Appliance Repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gilbert, az

Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports WHIRLPOOL dryer is not heating. Model WED9600TWQ CAUSE: Inspected dryer wall receptacle for proper voltage to the dryer, voltage to the dryer is normal at the time of inspection. Inspected dryer terminal block and cord for visible shorts, no shorts found at terminal block or cord at the time of inspection. Inspected dryer heater continuity on the heater element, heating element tested good at the time of inspection, Tested thermal safety for continuity, no continuity present, Found dryer thermal safety shorted out. CORRECTION: Replaced dryer thermal safety and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports WHIRLPOOL washer is leaving debri on clothes CAUSE: Unable to duplicate customer concern at this time. Washer is performing as designed at time of inspection.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports GE oven is not working. Display is not present. Model PGB918SEM4SS DIAGNOSTIC AND CAUSE: Inspected oven for proper wall outlet voltage to the oven, Output voltage normal at the time of inspection. Inspected voltage input at the main control board, input voltage to the main control board normal at the time of inspection. Found oven main control board failed. CORRECTION: Replaced and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Samsung Washer is not draining or spinning Model WF350ANW/xaa02 DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer report GE refrigerator is not getting cold on refrigerator side.Model GSH25JSDESS DIAGNOSTIC AND CAUSE: Inspected compressor operation, evaporator fan and condenser fan operation, all normal. Found frost build up on evaporator coils. Tested defrost heater for continuity, Found defrost heater and limiter shorted. CORRECTION: Replaced defrost heater and limiter. Tested operation, all normal upon completion.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports LG R/F coil cooktop burner is not working. Model DIAGNOSTIC AND CAUSE: Inspected for proper voltage from wall to cooktop terminal block, voltage is normal. Inspected voltage from terminal block to the main control input line, voltage was normal. Inspected voltage from the main control to the infinite input, voltage was normal. Inspected voltage from R/F infinite switch to the burner receptacle, found the burner receptacle and burner shorted out.CORRECTION: Replaced R/F burner and burner receptacle, operation now normal.


Spencer B.

Spencer B. Job Checkin

Service call, GE dishwasher Model GLD5660W10SS door striker not pushing down door latch button fully and stops cycle. adjusted striker to proper position and has helped now already. Est on replacing all door latch pieces $263.55.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports GE refrigerator is not as cold as it should be. Model GYE22KMHGES DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports SAMSUNG washer is not working CAUSE: Found washer pressure hose failed CORRECTION: Replaced and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Samsung ice maker is not making ice.Model RS263BBSH/XAA DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Samsung Refrigerator ice maker is not making ice. Model RS263BBSH/XAA DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Spencer B.

Spencer B. Job Checkin

(requested week out) est $235 (dispenser heat kit) Ref is dispenser is not working G...


Steve R.

Steve R. Job Checkin

Replaced left front infinite switch, and coil cup. Tested normal function


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports that the WHIRLPOOL Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports dryer is not heating. CAUSE: Inspected dryer wall receptacle for proper voltage to the dryer, voltage to the dryer is normal at the time of inspection. Inspected dryer terminal block and cord for visible shorts, no shorts found at terminal block or cord at the time of inspection. Inspected dryer heater continuity on the heater element, heating element tested good at the time of inspection, Tested thermal safety for continuity, no continuity present, Found dryer thermal safety shorted out. CORRECTION: Replaced dryer thermal safety and tested. Operation now normal. CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged wi