18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for glendale, az

Rated 4.9 out of 5 stars based on 13 customer reviews

Great and quick service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly and done reasonably soon

Chris had to get the necessary part and come back the next day. Didn’t take long , and our problem was solved. (Didn’t receive the receipt, though.)

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Carlos was very friendly and explained the details of servicing our dryer we will definitely request him again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service very personable

Carlos was early, did a great job and explained things as he went.

  • Overall Experience
  • Quality
  • Price
  • Convenience

professional knowledgeable and fair

Pleased that we were told the price window before accepting the replacement part seems most everything we have had to have repaired recently begins at $225.00 plus so this was in line!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Technician was very knowledgeable, friendly and explained the problems as he fixed them.

excellence experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service & Price

Very friendly, great with dog, explained what happened and gave advice on ow to prevent future occurrences - highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very good service

service man got to our house when He said He would be there

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service, on time and nice technition

would recommend to friends

  • Overall Experience
  • Quality
  • Price
  • Convenience

Was great service

Like how fast problem was taken care of

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for glendale, az

Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports GE washer is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for voltage output, voltage output to washer normal at the time of inspection. Inspect voltage to control, voltage to control was normal at the time of inspection. Inspected signal from control to washer shift actuator, found washer shift actuator failed. CORRECTION: Replaced washer shift actuator and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports Amanan Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports WHIRLPOOL washer is not draining. CAUSE: Found washer interlock switch broken. CORRECTION: Bypassed interlock switch and tested, operation now normal. No Warranty


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports SAMSUNG dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports oven is not working. DIAGNOSTIC AND CAUSE: Inspected oven for proper wall outlet voltage to the oven, Output voltage normal at the time of inspection. Inspected voltage input at the main control board, input voltage to the main control board normal at the time of inspection. Found oven main control board failed. CORRECTION: Replaced and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports dishwasher is leaking. DIAGNOSTIC AND CAUSE: Inspected water supply lines to the dishwasher, supply lines are normal at the time of inspection. Inspected dishwasher water valve for leaks, dishwasher water valve is normal. Filled dishwasher with water to inspect for leaks, found dishwasher door gasket failed. CORRECTION: Replaced door gasket and tested for leaks. Operation now normal. Replaced temp knob for washer.


Carlos V.

Carlos V. Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports dryer is not heating. CAUSE: Inspected dryer wall receptacle for proper voltage to the dryer, voltage to the dryer is normal at the time of inspection. Inspected dryer terminal block and cord for visible shorts, no shorts found at terminal block or cord at the time of inspection. Inspected dryer heater continuity on the heater element, heating element tested good at the time of inspection, Tested thermal safety for continuity, no continuity present, Found dryer thermal safety shorted out. CORRECTION: Replaced dryer thermal safety and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice and debris, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal. CONCERN Customer reports refrigerator broken door handle CAUSE: Found Broken door handle bad CORRECTION: install door handle and tested. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports dryer is not working. CAUSE: Found dryer had debris stuck in blower housing. CORRECTION: Removed debris from blower housing and tested, operation now normal.


Nick H.

Nick H. Job Checkin

CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal. CONCERN: Customer reports refrigerator is not getting cold on refrigerator side. DIAGNOSTIC AND CAUSE: Inspected compressor operation, evaporator fan and condenser fan operation, all normal. Found frost build up on evaporator coils. Tested defrost heater for continuity, Found defrost heater and limiter shorted. CORRECTION: Replaced defrost heater and limiter. Tested operation, all normal upon completion. CONCERN: Customer reports refrigerator is not working properly. CAUSE: Found refrigerator defrost timer failed. CORRECTION: Replace