18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for mesa, az

Rated 4.9 out of 5 stars based on 44 customer reviews

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Doug was awesome. I’ve had him out several times and every time he has done a great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

David is very knowledgeable about my particular appliances.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service

Great service, and friendly staff.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Warentee is awesome

Doug fixed my refrigerator/freezer. Appointment date was timely. He was timely, professional, personable and my dog liked him too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Called before he came, arrived on time worked quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service! Very knowledgeable.

Doug was so great and really knows his stuff. He fixed out fridge and even did some cleaning of the dust and things in the back to keep it running better for free! I highly recommend him and this company. They were also able to squeeze us in the same day we called!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service ever!

Completely satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.


Response from Affordable Appliance Repair:

RONNA, Thank you so much for taking the time to response and review our company. I as an owner always appreciate when a client tells me how we performed as a company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mesa, az

Doug D.

Doug D. Job Checkin

CONCERN: Customer reports washer is not agitating. CAUSE: Washer agitator gears stripped. CORRECTION: Replaced agitator gears and tested, operation now normal. No leaks upon completion.


David R.

David R. Job Checkin

CONCERN Customer reports refrigerator is leaking water into refrigerator when dispensing. CAUSE: Found cracked water tank. CORRECTION: Replaced and tested. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports dishwasher door is falling. CAUSE: Found dishwasher right door spring failed. Customer would like to replace both. CORRECTION: Replaced and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dishwasher is not draining properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to dishwasher, voltage normal at the time of inspection. Inspected voltage to main control input, dishwasher main control input voltage normal at the time of inspection. Inspected main control output voltage to the dishwasher drain pump, main control output voltage, normal at the time of inspection. Inspected voltage to drain pump and found proper operating voltage to Dishwasher drain pump, dishwasher drain pump impeller still not working. Dishwasher drain pump failed. CORRECTION: Replaced dishwasher drain pump and tested, operation now normal. Customer aware of damage under sink area.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal CONCERN: Dryer stops too soon on sensor dry. DIAGNOSTIC AND CAUSE: sensor bars are dirty. Dryer vent cleanCORRECTION: Performed dryer vent cleaning, cleaned moisture sensor bars, tested for restrictions, operation now normal


Rene  G.

Rene G. Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested, checked for leaks. No leaks at this time. Operation now normal.


Dustin Z.

Dustin Z. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports refrigerator not cooling. CAUSE: Found compressor overload/relay switch failure. CORRECTION: Installed compressor hard start kit, and tested. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN Customer reports refrigerator not cooling. CAUSE: Found compressor overload/relay switch failure. CORRECTION: Installed compressor hard start kit, and tested. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports refrigerator has water forming ice at freezer bottom. CAUSE: Found defrost drain & line clogged with ice & debris. CORRECTION: Cleared ice & debris; Installed defrost drain tube kit, and tested. Operation now normal. No leaks upon completion.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CAUSE: Found refrigerator water filter housing failed. CORRECTION: Replaced refrigerator water filter housing and tested for leaks. Operation now normal.