Donald D.

Donald D. Job Checkin

CONCERN: Customer reports Whirlpool dishwasher is not working. Model DU915PWPB0 DIAGNOSTIC AND CAUSE: Inspected wall output for proper voltage, voltage is normal. Inspected voltage from dishwasher junction box to the dishwasher control board, voltage to the control board is normal. Inspected voltage from control board output to the dishwasher thermal fuse, found dishwasher thermal fuse shorted. CORRECTION: Replaced dishwasher fuse link and wiring harness kit, operation now normal.


David R.

David R. Job Checkin

CONCERN Customer reports refrigerator section is not cold enough. CAUSE: Found air return channel full of frost/ice. Damper door operation normal. Likely freezer was left open for extended time. CORRECTION: Defrosted air return, checked damper operation, and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Dishwasher rack is not operating properly. DIAGNOSTIC AND CAUSE: dishwasher rack adjuster rollers failed. CORRECTION: Replaced with updated adjuster roller kit and tested, operation is now normal. CONCERN: Dishwasher bottom rack is not sliding properly. DIAGNOSTIC AND CAUSE: dishwasher rack rollers failed. CORRECTION: Replaced rollers and tested, operation is now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports dryer has a burning smell while running. CAUSE: Internal dryer cabinet filled with blow by lint. CORRECTION: Disassembled dryer and cleaned internal dryer cavity and reassembled unit. Operation is now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Found debris stuck in drain pump impeller restricting operation. CORRECTION: Removed drain pump and cleared debris. Tested unit operation is now normal.


David R.

David R. Job Checkin

CONCERN: Customer states washer is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall receptacle for proper outlet voltage to washer, wall receptacle voltage is normal at the time of inspection. Inspected washer controls for proper input voltage, voltage normal at time of inspection. Inspected washer interlock continuity, found washer interlock switch failed. CORRECTION: Replaced washer interlock switch and tested on all cycles, operation now normal.


Michael H.

Michael H. Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


David R.

David R. Job Checkin

Sub zero refrigerator is icing up and temperature is rising. Doubletree/Invergordon CONCERN: Customer reports refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


David R.

David R. Job Checkin

CONCERN: Customer reports GE Refrigerator ice maker is not making ice and refrigerator does not dispense water. Model GSH25SGPCSS DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, found microtubing leaking when dispensing. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker, replaced portion of microtubing, and tested. Operation now normal, no leaks upon completion. Doubletree/Invergordon IN Paradise Valley

CONCERN: Customer reports GE Refrigerator ice maker is not making ice and refrigerator does not dispense water. Model GSH25SGPCSS DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, found microtubing leaking when dispensing. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker, replaced portion of microtubing, and tested. Operation now normal, no leaks upon completion. Doubletree/Invergordon IN Paradise Valley

Michael H.

Michael H. Job Checkin

Refrigerator ice build up. Lincoln/32nd St. CONCERN: Customer reports refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Also defrosted evaporator coils. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


David R.

David R. Job Checkin

Maytag Dryer no spin. Lincoln/37th st. CONCERN: Customer reports dryer will not tumble clothes. CAUSE: Found dryer belt failed. CORRECTION: Replaced dryer belt and tested. Operation now normal. Also replaced light bulb. CONCERN: Customer reports refrigerator lights do not work. CAUSE: Found door switch failed. CORRECTION: replaced switch and tested. Operation now normal.


David R.

David R. Job Checkin

GE Monogram Microwave not working. Model# ZE2160SF05 Lincoln/Tatum. WB27X10567 CONCERN: Microwave display is not working. CAUSE: Found thermal safety shorted out. Also the main fuse shorted and a connector on thermal fuse melted. CORRECTION: Removed microwave from cabinet to access thermal safety. Replaced thermal safety, repaired connector, replaced main fuse, and tested, operation now normal.


David R.

David R. Job Checkin

Ice machine slow to produce. Doubletree/Scottsdale CONCERN: Customer reports ice maker is not making much ice. CAUSE: Nozzles clogged with debris, overdue for cleaning. CORRECTION: Cleaned with solution and flushed overflow and drain hoses, cleaned debris from nozzles.


David R.

David R. Job Checkin

Ice maker in freezer and under counter beverage cooler issue. SCOTTSDALE/MOCKINGBIRD CONCERN 1: Customer requests ice machines cleaned per maintenance schedule. CORRECTION 1: Cleaned with solution and bleach. CONCERN 2: Customer reports freezer is not producing ice. CAUSE 2: Found water valve failure. CORRECTION 2: Replaced water valve, defrosted ice build-up in feed tube, and tested. Operation now normal.


Michael H.

Michael H. Job Checkin

Maytag Dryer no heat Tatum/Doubletree